Stefan H Hohnloser, Hussein R Al-Khalidi, Craig M Pratt, Jose M Brum, Daljit S Tatla, Patrick Tchou, Paul Dorian
Journal: European heart journal 2007;27(24):3027-32
PMID: 17050586
AIMS
The purpose of this study was to assess the incidence, features, and clinical sequelae of 'electrical storm' (ES).
METHODS AND RESULTS
This study is a prospectively designed secondary analysis of SHIELD; a randomized trial of azimilide for suppression of ventricular tachycardia/fibrillation (VT/VF) leading to implanted cardioverter defibrillator (ICD) therapies. Systematic and rigorous follow-up and blinded adjudication of ICD therapy allowed identification of all ESs (>/=3 separate VT/VF episodes leading to ICD therapies within 24 h). Of 633 ICD recipients, 148 (23%) experienced at least one ES over 1-year follow-up. No clinical predictors of ES were identified. Frequent VT episodes accounted for 91% of all ESs, with the remaining being VF alone or both VT plus VF. ES led to a 3.1-fold increase in arrhythmia-related hospitalization (95% CI 2.3-4.3; P<0.0001) compared with patients with isolated VT/VF, and to a 10.2-fold increase (95% CI 6.4-16.3; P<0.0001) compared with patients without VT/VF. Compared with placebo, azimilide (75 and 125 mg/day) reduced the risk of recurrent ES by 37% (HR=0.63, 95% CI 0.35-1.11, P=0.11) and 55% (HR=0.45, 95% CI 0.23-0.87, P=0.018), respectively. However, the reduction in time-to-first ES did not reach statistical significance by both doses (75 and 125 mg) of azimilide (HR=0.82, 95% CI 0.56-1.19, P=0.29 and HR=0.69, 95% CI 0.46-1.04, P=0.07), respectively.
CONCLUSION
ES is common and unpredictable in ICD recipients and it is a strong predictor of hospitalization.
© Copyright 2026, Nutrition Evidence
We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.