Echo-Doppler and clinical evaluations to define hemodynamic profile in patients with chronic heart failure: accuracy and influence on therapeutic management.

Soccorso Capomolla, Monica Ceresa, GianDomenico Pinna, Roberto Maestri, Maria Teresa La Rovere, Oreste Febo, Angelo Rossi, Vincenzo Paganini, Angelo Caporotondi, Giampaolo Guazzotti, Marco Gnemmi, Andrea Mortara, Franco Cobelli

Journal: European journal of heart failure 2005;7(4):624-30

PMID: 15921804

Abstract

BACKGROUND

Correct classification of chronic heart failure (CHF) patients by dual evidence of congestion and adequate perfusion is the primary clinical focus for management.

OBJECTIVES

To evaluate the accuracy of echo-Doppler compared with clinical evaluation in determining the hemodynamic profile of patients with CHF; and to compare therapeutic changes based on hemodynamic or echo-Doppler findings.

METHODS

Three hundred and sixty-six consecutive CHF patients (ejection fraction 25+/-7%) in sinus rhythm, undergoing evaluation for cardiac transplantation, underwent physical examination prior to right heart catheterization and echo-Doppler studies. Subsequently, patients were randomized to therapeutic optimization using either right heart catheterization or echo-Doppler data. The end-points were: identification of low cardiac output (cardiac index <2.2 l/min/m(2)); high pulmonary wedge pressure (PWP >18 mm Hg); high right atrial pressure (RAP >5 mm Hg) and analysis of therapeutic changes made in response to the right heart catheterization and echo-Doppler studies.

RESULTS

Echo-Doppler showed better accuracy in estimating abnormal hemodynamic indices than clinical variables (cardiac index <2.2 l/min/m(2): echo positive predictive accuracy (PPA) 98% vs. clinical PPA 52% p<0.00001; PWP >18 mm Hg: echo PPA 85% vs. clinical PPA 76% p=0.0011; RAP >5 mm Hg: echo PPA 82% vs. clinical PPA 57% p<0.00001). When applied to individual patients, the echo-Doppler assessment was more accurate than clinical evaluation in defining the different hemodynamic profiles: wet/cold (89% vs. 13%, p<0.0001); wet/warm (73% vs. 30%, p<0.0001); dry/cold (68% vs. 12%, p<0.0001); dry/warm (88% vs. 51%, p<0.0001). Therapeutic decision-making based on echo-Doppler findings was similar to that based on hemodynamics.

CONCLUSION

Echo-Doppler hemodynamic monitoring proved accurate in estimating hemodynamic profiles and influenced therapeutic management.

Address: Fondazione Salvatore Maugeri, IRCCS, -PAVIA-Istituto Scientifico di Montescano, Italy. [email protected]
Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.