L V Marino, Praneel Ramchandra, Narendra Nathoo
Journal: Journal of clinical neuroscience : official journal of the Neurosurgical Society of Australasia 2006;12(4):435-7
PMID: 15925776
AIM
To compare the efficacy of blind transpyloric placement using a specifically designed nasojejunal tube (NJT) versus a standard nasogastric tube (NGT) in severe head injury (SHI).
METHODS
This was a randomised trial conducted in a neurosurgical intensive care unit. Fourteen patients were enrolled with a Glasgow Coma Score (GCS) less than 8 (mean 6.8 SEM+/-0.36). Patients were randomised to receive either NJT or NGT.
RESULTS
There was an 83% (5/6 patients) spontaneous jejunal placement rate of NJT past the ligament of Treitz. The 17% (1/6 patients) jejunal placement failure rate for NJT was due to inappropriate technique. A 100% (8/8 patients) failure of the unweighted NGTs to pass through the pylorus into the jejunum was recorded (P=0.002).
CONCLUSION
In SHI, the specifically designed self-propelling NJT was effective in spontaneous transpyloric placement past the ligament of Treitz within 12h of introduction into the gastric cavity. The standard un-weighted NGT was ineffective. Additional studies are warranted to determine the clinical efficacy of this self-propelling NJT.