Takuji Toyama, Hiroshi Hoshizaki, Ryotaro Seki, Naoki Isobe, Hitoshi Adachi, Shigeto Naito, Shigeru Oshima, Koichi Taniguchi
Journal: Circulation journal : official journal of the Japanese Circulation Society 2004;68(4):348-54
PMID: 15056833
BACKGROUND
GIK-201Tl imaging reportedly improves the detection of viable myocardium, so the present study evaluated whether it can detect myocardial viability after acute myocardial infarction (AMI).
METHODS AND RESULTS
Resting 201Tl and 99mTc-pyrophosphate (PYP) dual single photon emission computed tomography (SPECT) and 201Tl SPECT after 201Tl with GIK (10% glucose, insulin 5 U, and KCl 10 mmol) infusion (GIK-201Tl) were performed in 25 AMI patients within 10 days of admission. GIK-201Tl SPECT images were obtained immediately and 4 h after infusion. Left ventriculography (LVG) was performed within 3 weeks and at 6 months when follow-up 201Tl SPECT was also performed. From 20 SPECT segments, both the summed defect score (RDS) and the number of defect segments (ES) were calculated. The infarcted area was defined as 99mTc-PYP uptake segments. Wall motion was estimated in 7 LVG segments. The ES of R-201Tl (5.5 +/- 2.8), immediate GIK-201Tl (4.0 +/- 2.3), and 4-h GIK-201Tl (5.6 +/- 2.7) were lower than that of 99mTc-PYP (7.5 +/- 4.1) (p<0.05), and the ES had significantly declined 6 months later on 201Tl (3.5 +/- 2.8) (p<0.05). Although the RDS of R-201Tl (11.3 +/- 7.9) and 4-h GIK-201Tl (11.2 +/- 6.3) were greater than at the 6-month 201Tl (7.1 +/- 6.5), immediate GIK-201Tl (7.4 +/- 6.5) was equivalent to follow-up 201Tl. The sensitivity of immediate GIK-201Tl was highest among the imaging methods.
CONCLUSION
To detect myocardial viability after AMI, early imaging with GIK-201Tl is more useful than resting 201Tl imaging.
Full Text Sources:
Medical:
Miscellaneous:
© Copyright 2026, Nutrition Evidence
We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.