Comparison of the diagnostic performance of non-contrast MR angiography and planar V/Q scintigraphy for pulmonary embolism: a systematic review and meta-analysis.

Matheus Zanon, Stephan Altmayer, Jürgen Biederer, Bruno Hochhegger, Ricardo F Silva, Jeanne B Ackman, Gabriele C Forte, Liisa L Bergmann, Rubens Gabriel Feijó Andrade

Journal: European radiology 2025;35(8):4814-4823

PMID: 39863727

Abstract

OBJECTIVES

To conduct a meta-analysis of the diagnostic performance of non-contrast magnetic resonance pulmonary angiography (NC-MRPA) and ventilation-perfusion (V/Q) scintigraphy for the detection of acute pulmonary embolism (PE).

MATERIALS AND METHODS

Systematic searches of electronic databases were conducted from 2000 to 2024. Primary outcomes were per-patient sensitivity and specificity of NC-MRPA and V/Q scintigraphy. The pooled sensitivities, specificities, and 95% confidence intervals (95% CI) were calculated using a random-effect analysis. Summary receiver-operating characteristic (SROC) curves and the area under the curve (AUC) were obtained.

RESULTS

A total of 3709 studies (1941 NC-MRPA studies) were identified through systematic searches, with eight published MRI and nine published V/Q investigations meeting inclusion criteria. The results showed that NC-MRPA had a pooled sensitivity of 0.88 (95% CI: 0.83-0.91) and specificity of 0.97 (95% CI: 0.93-0.98), yielding an AUC of 0.92 (95% CI: 0.85-0.96). V/Q scanning had a pooled sensitivity of 0.81 (95% CI: 0.76-0.85) and specificity of 0.84 (95% CI: 0.74-0.91), yielding an AUC of 0.87 (95% CI: 0.75-0.91). The pooled proportion of non-diagnostic tests for V/Q scans (34.7%, 95% CI: 30.8-38.7) was greater than that of NC-MRPA studies (3.31%, 95% CI: 1.65-4.97).

CONCLUSION

This meta-analysis suggests that NC-MRPA is more specific than V/Q scintigraphy for the detection of PE, with comparable accuracy and sensitivity. NC-MRPA yielded fewer non-diagnostic scans than V/Q scintigraphy and is a feasible alternative imaging modality for diagnosing PE in patients for whom intravenous contrast administration poses a substantive risk.

KEY POINTS

Question V/Q lung scintigraphy has been used as a reserve, alternative modality for patients who cannot undergo CT pulmonary angiography. Findings Non-contrast MR angiography (MRA) is a feasible alternative for diagnosing PE in patients for whom intravenous iodinated contrast administration poses a substantial risk. Clinical relevance Non-contrast MRA provides similar sensitivity and superior specificity to V/Q scintigraphy for diagnosing PE, without ionizing radiation exposure.

© 2025. The Author(s), under exclusive licence to European Society of Radiology.

Address: Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Brazil.; Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Brazil.; Federal University of Health Sciences of Porto Alegre, Porto Alegre, Brazil.; Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA.; Stanford Hospital, Stanford University Medical Center, Stanford, CA, USA.; University Hospital of Heidelberg, Heidelberg, Germany.; University of Kentucky, Lexington, KY, USA.; Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Brazil. [email protected].; Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Brazil. [email protected].; Federal University of Health Sciences of Porto Alegre, Porto Alegre, Brazil. [email protected].; University of Florida, Gainesville, FL, USA. [email protected].

Link outs

Subscription / membership required

Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.