Raffaele Pulli, Michele Antonello, Luca Bertoglio, Mauro Gargiulo, Emiliano Chisci, Emanuele Ferrero, Luca Mezzetto, Giacomo Isernia, Giovanni Pratesi, Stefano Michelagnoli
Journal: European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery 2025;69(3):392-402
PMID: 39557380
OBJECTIVE
Carbon dioxide (CO) angiography has emerged as a viable alternative to regular iodinated contrast medium (ICM) for guiding endovascular aneurysm repair (EVAR) procedures. This study aimed to evaluate the feasibility and safety of a standardised EVAR procedure using only CO angiography.
METHODS
A prospective, multicentre, national study enrolled consecutive patients between January 2023 and January 2024 with asymptomatic abdominal aortic aneurysms measuring ≥ 55 mm and for whom a standard endovascular graft (instructions for use) was anatomically feasible. The study involved the use of an automatic CO injector to standardise intra-operative imaging. A strategy comprising five standardised steps was devised to visualise a target vessel (TV) that could not be seen during the first CO angiogram. The five steps were: (A) place the introducer closer to the TV; (B) tilt the table by 5 - 10° in the direction opposite to the TV; (C) selectively cannulate the TV; (D) cannulate the contralateral gate (only for repositionable devices); CO angiography was repeated in steps 1 - 2; and (E) use ICM.
RESULTS
Two hundred and ninety-three patients were enrolled (10 centres), with a median age of 78 (interquartile range [IQR] 72, 83) years; 256 (87.4%) were male. The overall procedure time, fluoroscopy time, and injected CO volume were 90 (IQR 65, 125) minutes, 15 (IQR 10, 22) minutes, and 600 (IQR 400, 800) mL, respectively. The 30 day mortality, complication, and re-intervention rates were 0.3% (n = 1), 6.8% (n = 20), and 2.4% (n = 7), respectively. CO related adverse events were rare (1%; n = 3) and minor. A zero iodine contrast EVAR procedure was feasible in 240 (patients 81.9%). The five standardised steps were used extensively: step A, 170 procedures (58.0%); step B, 109 procedures (37.2%); step C, 21 procedures (7.2%); step D, 14 procedures (4.8%); and step E, 53 procedures (18.1%), with a median volume of 20 (IQR 10, 35) mL. Significant predictors for ICM use were aneurysm diameter > 70 mm and a lowermost renal artery positioned between 3 and 9 o'clock.
CONCLUSION
This study demonstrated that the standardised zero iodine contrast EVAR protocol reported here is both safe and feasible and is applicable in 82% of consecutive non-selected patients. Limitations primarily arose from anatomical factors, and adjunctive standardised manoeuvres can effectively address these challenges in most cases.
Copyright © 2024 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.
© Copyright 2026, Nutrition Evidence
We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.