Enhancing indoor air quality and cardiopulmonary health in patients with asthma by photocatalytic oxidation and filters air cleaner.

Jia Lin Zhang, Guan-Yu Liao, Hong-Yi Lin, Jie-An Xie, Wan-Chen Li, Huang-Chi Chen, Da Wei Wu, Huai-Lei Juan, Jia-Yu Kuo, Pei-Shih Chen

Journal: Journal of hazardous materials 2025;482():136573

PMID: 39581037

Abstract

BACKGROUND

Air purifiers can enhance indoor air quality and health outcomes, and studies have primarily focused on filters and particulate matter (PM) in households. Photocatalytic oxidation (PCO) is a promising technique for eliminating gaseous pollutants and bioaerosols. However, no field study was conducted in household. Therefore, this study evaluated the effects of the PCO and PCO + filters intervention on indoor air pollutants and cardiopulmonary endpoints in households.

METHODS

A randomized, double-blind crossover clinical trial was conducted. Indoor air pollutants, including PM, bioaerosols, and gaseous pollutants and cardiopulmonary endpoints including lung function, fractional exhaled nitric oxide (FeNO), respiratory symptoms, and blood pressure were assessed before and after intervention.

FINDINGS

This was the first study to evaluate the effects of PCO and PCO + filters interventions on indoor air pollutants and cardiopulmonary health in households. Indoor total volatile organic compounds (TVOC) and sulfur dioxides (SO) significantly reduced after PCO intervention, however, we also observed the significant reduction in percentage of predicted values of forced vital capacity (FVC%) and forced expiratory volume in 3 s (FEV%) and increased in FeNO after 13 days of PCO intervention. The PCO + filters intervention significantly reduced the levels of indoor PM, PM, PM, PM, total suspended particulate matter, ultrafine particles, airborne bacteria, fungi, endotoxin, mites, TVOC, nitrogen dioxide, and SO, and marginal reduction in carbon monoxide. However, indoor carbon dioxide significantly increased after PCO/PCO + filters intervention. As for cardiopulmonary health, FVC%, and FEV1 % marginally increased 7 days after the PCO + filters intervention.

Copyright © 2024 Elsevier B.V. All rights reserved.

Address: Department of Public Health, College of Health Science, Kaohsiung Medical University, Kaohsiung City, Taiwan, ROC.; Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Kaohsiung Municipal Siaogang Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan, ROC.; Department of Public Health, College of Health Science, Kaohsiung Medical University, Kaohsiung City, Taiwan, ROC; Institute of Environmental Engineering, College of Engineering, National Sun Yat-Sen University, Kaohsiung City, Taiwan, ROC; Department of Medical Research, Kaohsiung Medical University Hospital, Kaohsiung City 807, Taiwan, ROC; Research Center for Precision Environmental Medicine, Kaohsiung Medical University, Kaohsiung City, Taiwan, ROC; Institute of Wildlife Conservation, College of Veterinary Medicine, National Pingtung University of Science and Technology, Pingtung City, Taiwan, ROC. Electronic address: [email protected].