A Mechteld Lehr, Diyar Delawi, Eric A Hoebink, Diederik H R Kempen, Job L C van Susante, Moyo C Kruyt, Hilde W Stempels, Inge A A A Wiljouw
Journal: Spine 2024;49(19):1323-1331
PMID: 38881258
STUDY DESIGN
A multicenter randomized controlled noninferiority trial with intrapatient comparisons.
OBJECTIVE
The aim of this study was to determine noninferiority of a slowly resorbable biphasic calcium phosphate with submicron microporosity (BCP<μm, MagnetOs Granules) as an alternative for autograft in instrumented posterolateral fusion (PLF).
SUMMARY OF BACKGROUND DATA
Successful spinal fusion with a solid bone bridge between the vertebrae is traditionally achieved by grafting with autologous iliac bone. However, the disadvantages of autografts and unsatisfactory fusion rates have prompted the exploration of alternatives, including ceramics. Nevertheless, clinical evidence for the standalone use of these materials is limited.
METHODS
Adults indicated for instrumented PLF (1 to 6 levels) were enrolled at 5 participating centers. After bilateral instrumentation and fusion-bed preparation, the randomized allocation side (left or right) was disclosed. Per segment 10 cc of BCP<μm granules (1 to 2 mm) were placed in the posterolateral gutter on one side and 10 cc autograft on the contralateral side. Fusion was systematically scored on 1-year follow-up CT scans. The study was powered to detect >15% inferiority with binomial paired comparisons of the fusion performance score per treatment side.
RESULTS
Of the 100 patients (57 ± 12.9 y, 62% female), 91 subjects and 128 segments were analyzed. The overall posterolateral fusion rate per segment (left and/or right) was 83%. For the BCP<μm side only the fusion rate was 79% versus 47% for the autograft side (difference of 32 percentage points, 95% CI, 23-41). Analysis of the primary outcome confirmed the noninferiority of BCP<μm with an absolute difference in paired proportions of 39.6% (95% CI, 26.8-51.2; p < 0.001).
CONCLUSION
This clinical trial demonstrates noninferiority and indicates superiority of MagnetOs Granules as a standalone ceramic when compared to autograft for posterolateral spinal fusion. These results challange the belief that autologous bone is the most optimal graft material.
Copyright © 2024 The Author(s). Published by Wolters Kluwer Health, Inc.