Christian D Taeger, Oliver Friedrich, Raymund E Horch, Caroline Drechsler, Annika Weigand, Fabio Hopf, Carol I Geppert, Frank Münch, Torsten Birkholz, Carina Wenzel, Sebastian Geis, Lukas Prantl, Rainer Buchholz, Konstantin Präbst
Journal: Clinical hemorheology and microcirculation 2024;79(2):257-267
PMID: 28759964
BACKGROUND
Extracorporeal perfusion (EP) is moving into focus of research in reconstructive and transplantation medicine for the preservation of amputates and free tissue transplants. The idea behind EP is the reduction of ischemia-related cell damage between separation from blood circulation and reanastomosis of the transplant. Most experimental approaches are based on a complex system that moves the perfusate in a circular course.
OBJECTIVE AND METHODS
In this study, we aimed to evaluate if a simple perfusion by an infusion bag filled with an electrolyte solution can provide acceptable results in terms of flow stability, oxygen supply and viability conservation for EP of a muscle transplant. The results are compared to muscles perfused with a pump system as well as muscles stored under ischemic conditions after a one-time intravasal flushing with Jonosteril.
RESULTS
With this simple method a sufficient oxygen supply could be achieved and functionality could be maintained between 3.35 times and 4.60 times longer compared to the control group. Annexin V positive nuclei, indicating apoptosis, increased by 9.7% in the perfused group compared to 24.4% in the control group.
CONCLUSIONS
Overall, by decreasing the complexity of the system, EP by one-way infusion can become more feasible in clinical situations.