Farida Gadalla, Sung-Hee Rhim Lee, Kue C Choi, Jill Fong, Matthew C Gomillion, Barbara L Leighton
Journal: Canadian journal of anaesthesia = Journal canadien d'anesthesie 2003;50(4):382-5
PMID: 12670816
PURPOSE
To determine if injecting 10 mL saline before epidural catheter threading (pre-cannulation epidural fluid injection) can decrease the incidence of iv epidural catheter placement during combined spinal-epidural (CSE) labour analgesia.
METHODS
One hundred healthy women requesting CSE labour analgesia with either fentanyl 20 microg or sufentanil 10 microg were prospectively randomized to receive either no epidural injection (dry group, n = 50) or epidural 10 mL saline injection (saline group, n = 50) before epidural catheter placement. A nylon multiport catheter was then threaded 3-5 cm into the epidural space and the needle was removed. We diagnosed iv catheter placement if blood was freely aspirated, if the mother became tachycardic after injection of epinephrine 15 microg, or if intracardiac air was heard (using ultrasound) after injection of air 1.5 mL.
RESULTS
Intravenous epidural catheter placement occurred in one saline and ten dry group patients (P < 0.01). No complications of excessive cephalad intrathecal opioid spread (i.e., difficulty swallowing, hypoxemia, or respiratory arrest) occurred.
CONCLUSIONS
Injecting 10 mL or saline through the epidural needle after intrathecal opioid injection and before threading the catheter significantly decreased accidental venous catheter placement without any apparent increase in complications from excessive cephalad intrathecal opioid spread.