Young-Hoo Kim, S-H Oh, J-S Kim, K-H Koo
Journal: The Journal of bone and joint surgery. American volume 2003;85(4):675-81
PMID: 12672844
BACKGROUND
The rate of failure of primary total hip arthroplasty in patients with osteonecrosis of the femoral head is higher than that in patients with osteoarthritis. The purpose of this prospective study was to document the clinical and radiographic results of arthroplasty with so-called third-generation cementing and the results of second-generation cementless total hip arthroplasty in ninety-eight consecutive patients with osteonecrosis of the femoral head.
METHODS
Fifty patients who had had simultaneous bilateral total hip arthroplasty with a cemented stem in one hip and a cementless stem in the other and forty-eight patients who had had a unilateral total hip arthroplasty with a cementless stem were included in the study. A cementless acetabular component was used in all hips. The presumed cause of the osteonecrosis was ethanol abuse in fifty-seven patients, unknown in twenty-seven, fracture of the femoral neck in nine, and steroid use in five. There were eighty men and eighteen women. The mean age at the time of the arthroplasty was 47.3 years (range, twenty-six to fifty-eight years). Clinical and radiographic evaluations were performed preoperatively; at six weeks; at three, six, and twelve months; and yearly thereafter. The average duration of follow-up was 9.3 years.
RESULTS
The average Harris hip scores in the group treated with unilateral arthroplasty (97 points) and the group treated with bilateral arthroplasty (94 points) were similar at the time of final follow-up. They were also similar between the group treated with cement (mean, 96 points) and that treated without cement (95 points). No component had aseptic loosening in either group. In one hip, a cemented femoral stem (2%) and a cementless cup were revised because of infection. Two cementless stems (2%) were revised because of fracture of the proximal part of the femur with loosening of the stem. Annual wear of the polyethylene liner averaged 0.22 mm in the group treated with cement (a zirconia head) and 0.14 mm in the group treated without cement (a cobalt-chromium head). The prevalence of osteolysis in zones 1 and 7 of the femur was 16% in the group treated with cement and 24% in the group treated without cement.
CONCLUSIONS
Advancements in surgical technique and better designs have greatly improved the long-term survival of cemented and cementless implants in young patients with osteonecrosis of the femoral head. Although there was no aseptic loosening of the components, a high rate of linear wear of the polyethylene liner and a high rate of osteolysis in these high-risk young patients remain challenging problems.
© Copyright 2026, Nutrition Evidence
We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.