Biosensors Based on Ion-Sensitive Field-Effect Transistors for HLA and MICA Antibody Detection in Kidney Transplantation.

Thu Zar Ma Ma Moe Min, Sonwit Phanabamrung, Woraphan Chaisriratanakul, Apirak Pankiew, Awirut Srisuwan, Kondee Chauyrod, Cholatip Pongskul, Chamras Promptmas, Chanvit Leelayuwat

Journal: Molecules (Basel, Switzerland) 2022;27(19):6697

PMID: 36235233

Abstract

This work demonstrates the ability of the Ion-Sensitive Field-Effect Transistor (ISFET)-based immunosensor to detect antibodies against the human leukocyte antigen (HLA) and the major histocompatibility complex class-I-related chain A (MICA). The sensing membrane of the ISFET devices was modified and functionalized using an APTES-GA strategy. Surface properties, including wettability, surface thickness, and surface topology, were assessed in each module of the modification process. The optimal concentrations of HLA and MICA proteins for the immobilization were 10 and 50 μg/mL. The dose-response curve showed a detection range of 1.98-40 µg/mL for anti-HLA and 5.17-40 µg/mL for anti-MICA. The analytical precision (%CV) was found to be 10.69% and 8.92% for anti-HLA and -MICA, respectively. Moreover, the electrical signal obtained from the irrelevant antibody was considerably different from that of the specific antibodies, indicating the specific binding of the relevant antibodies without noise interference. The sensitivity and specificity in the experimental setting were established for both antibodies (anti-HLA: sensitivity = 80.00%, specificity = 86.36%; anti-MICA: sensitivity = 86.67%, specificity = 88.89%). Our data reveal the potential of applying the ISFET-based immunosensor to the detection of relevant anti-HLA and -MICA antibodies, especially in the field of kidney transplantation.

Address: Department of Medical Laboratory Technology, University of Medical Technology, Mandalay, Patheingyi 05071, Myanmar.; Department of Clinical Immunology and Transfusion Sciences, Faculty of Associated Medical Sciences, Khon Kaen University, Khon Kaen 40002, Thailand.; The Centre for Research and Development of Medical Diagnostic Laboratories, Faculty of Associated Medical Sciences, Khon Kaen University, Khon Kaen 40002, Thailand.; Thai Microelectronic Center (TMEC), National Science and Technology Development Agency, Chachoengsao 24000, Thailand.; Division of Nephrology, Department of Medicine Khon Kaen University, Khon Kaen 40002, Thailand.; Department of Biomedical Engineering, Faculty of Engineering, Mahidol University, Nakhon Pathom 73170, Thailand.
Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.