Droplet nuclei are generated during colonoscopy and are decreased by the use of carbon dioxide and water immersion technique.

Shannon Melissa Chan, Tsz Wah Ma, Simon Chu, Hon Sok Fei, Kaori Futaba, Hon Chi Yip, Anthony Yuen Bun Teoh, Martin Chi-Sang Wong, Simon Siu Man Ng, Enders Kwok Wai Ng, Philip Wai Yan Chiu

Journal: Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society 2023;35(1):77-85

PMID: 35751478

Abstract

OBJECTIVES

The COVID-19 pandemic has raised concerns on whether colonoscopies (CS) carry a transmission risk. The aim was to determine whether CS are aerosol-generating procedures.

METHODS

This was a prospective observational trial including all patients undergoing CS at the Prince of Wales Hospital from 1 June to 31 July 2020. Three particle counters were placed 10 cm from each patient's anus and near the mouth of endoscopists and nurses. The particle counter recorded the number of particles of size 0.3, 0.5, 0.7, 1, 5, and 10 μm. Patient demographics, seniority of endoscopists, use of CO and water immersion technique, and air particle count (particles/cubic foot, dCF) were recorded. Multilevel modeling was used to test all the hypotheses with a post-hoc analysis.

RESULTS

A total of 117 patients were recruited. During CS, the level of 5 μm and 10 μm were significantly higher than the baseline period (P = 0.002). Procedures performed by trainees had a higher level of aerosols when compared to specialists (0.3 μm, P < 0.001; 0.5 μm and 0.7 μm, P < 0.001). The use of CO and water immersion techniques had significantly lower aerosols generated when compared to air (CO : 0.3, 0.5, and 0.7 μm: P < 0.001; water immersion: 0.3 μm: P = 0.048; 0.7 μm: P = 0.03). There were no significant increases in any particle sizes during the procedure at the endoscopists' and nurses' mouth. However, 8/117 (6.83%) particle count tracings showed a simultaneous surge of all particle sizes at the patient's anus and endoscopists' and nurses' level during rectal extubation.

CONCLUSION

Colonoscopy generates droplet nuclei especially during rectal extubation. The use of CO and water immersion techniques may mitigate these risks.

© 2022 Japan Gastroenterological Endoscopy Society.

Address: Department of Surgery, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong.; Jockey Club School of Public Health and Primary Care, The Chinese University of Hong Kong, Shatin, Hong Kong.
Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.