Abstract

The use of different approaches for design and results presentation of studies for the clinical performance evaluation of continuous glucose monitoring (CGM) systems has long been recognized as a major challenge in comparing their results. However, a comprehensive characterization of the variability in study designs is currently unavailable. This article presents a scoping review of clinical CGM performance evaluations published between 2002 and 2022. Specifically, this review quantifies the prevalence of numerous options associated with various aspects of study design, including subject population, comparator (reference) method selection, testing procedures, and statistical accuracy evaluation. We found that there is a large variability in nearly all of those aspects and, in particular, in the characteristics of the comparator measurements. Furthermore, these characteristics as well as other crucial aspects of study design are often not reported in sufficient detail to allow an informed interpretation of study results. We therefore provide recommendations for reporting the general study design, CGM system use, comparator measurement approach, testing procedures, and data analysis/statistical performance evaluation. Additionally, this review aims to serve as a foundation for the development of a standardized CGM performance evaluation procedure, thereby supporting the goals and objectives of the Working Group on CGM established by the Scientific Division of the International Federation of Clinical Chemistry and Laboratory Medicine.

Address: IFCC Scientific Division - Working Group on Continuous Glucose Monitoring.; Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany.; Diabetes Center Berne, Bern, Switzerland.; Department of Diabetes, Endocrinology, Nutritional Medicine and Metabolism, Inselspital Bern, Bern University Hospital and University of Bern, Bern, Switzerland.; School of Medical Sciences, Faculty of Medicine and Health, Örebro University, Örebro, Sweden.; Roche Diabetes Care GmbH, Mannheim, Germany.; Pirna, Germany.; Equalis AB, Uppsala, Sweden.; Clinical Biochemistry Department, KAT General Hospital, Athens, Greece.; Endokrinologie Diabetologie Bern, Bern, Switzerland.; Department of Pathology and Laboratory Medicine, University of California Davis Health, Sacramento, CA, USA.; Diabetes Research Institute, Mills-Peninsula Medical Center, San Mateo, CA, USA.; Vanderbilt University Medical Center, Nashville, TN, USA.; Department of Clinical Chemistry, Isala Clinics, Zwolle, the Netherlands.
Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.