Bioequivalue of two mycophenolate sodium enteric-coated tablets and the drug monitoring based on limited sampling strategy: A single-center, randomized, open-label, three-period, reference-replicated, crossover study.

Guangxun Xu, Zhendi Wang, Tianzhong Yan, Jinyu Li, Xiaofeng Zhou

Journal: Transplant immunology 2023;81():101923

PMID: 37652363

Abstract

OBJECTIVE

A mycophenolate sodium enteric-coated tablet has shown a satisfying anti-rejection effect in patients receiving solid organ transplantation. The current study evaluated the bioequivalence between the test (Ruiyirong®) vs. reference (Myfortic®) formulations by exploring equations for predicting their area under the concentration-time curve (AUC) using a limited sampling strategy in healthy subjects.

METHODS

Forty-eight healthy Chinese subjects were randomized into three administration sequences (test-reference-reference, reference-reference-test, and reference-test-reference) to receive the Ruiyirong or Myfortic treatment on days 1, 8, and 15.

RESULTS

The 90% confidential interval (CI) of the geometric mean ratios (test/reference) of maximum plasma concentration (C), the AUC from time 0 to the last timepoint (AUC), and the AUC from 0 to infinity (AUC) was 92.90%-110.57%, 96.91%- 101.80%, and 96.71%-101.84%, respectively. All these values fell into the bioequivalence criteria of 80.00%-125.00% (based on the criteria of the Food and Drug Administration). The adverse events were 10.4% in Ruiyirong test group and 14.6% in Myfortic reference group. Eight equations for estimating the AUC of the Ruiyirong test and Myfortic reference formulations were evaluated; most of them worked well with the R-value >0.8. Among the four chosen equations, the intragroup verification exhibited a high agreement with the R-value ranging from 0.857 to 0.971 and with the low predictive error (PE > 5% with absolute PE > 15%). Meanwhile, the intergroup verification indicated a high inter-agreement with the R-value ranging from 0.896 to 0.974 (all P < 0.001).

CONCLUSION

The Ruiyirong test vs. Myfortic reference formulations meet the bioequivalent criteria and are well tolerated. The further linear regression analysis explores eight equations predicting the AUC value and the chosen four equations for the Ruiyirong test and Mayfortic reference formulations are interchangeable.

Copyright © 2023 Elsevier B.V. All rights reserved.

Address: Hepato-Pancreato-Biliary Center, Beijing Tsinghua Changgung Hospital, Tsinghua University, Beijing 102218, China.; Department of Urology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Key Laboratory of Organ Transplantation, Ministry of Education, NHC, Chinese Academy of Medical Sciences, Wuhan 430030, China.; Department of Urology, Henan Provincial People's Hospital, Zhengzhou University People's Hospital, Henan University People's Hospital, Zhengzhou 450003, China.; Department of Urology Surgery, 909 Hospital, Joint logistic Support Force of PLA (Southeast Hospital, Xiamen University), Zhangzhou 363000, China.; Department of Urology, China-Japan Friendship Hospital, Beijing 100029, China. Electronic address: [email protected].