Elevations in End-Tidal CO 2 With CO 2 Use During Pediatric Endoscopy With Airway Protection: Is This Physiologically Significant?

Chinenye R Dike, Andrew Huang Pacheco, Elizabeth Lyden, David Freestone, Ojasvini Choudhry, Warren P Bishop, Mohanad Shukry

Journal: Journal of pediatric gastroenterology and nutrition 2023;76(5):660-666

PMID: 36821847

Abstract

BACKGROUND

Inflation of the gastrointestinal lumen is vital for proper visualization during endoscopy. Air, insufflated via the endoscope, is gradually being replaced with carbon dioxide (CO 2 ) in many centers, with the intention of minimizing post-procedural discomfort due to retained gas. Recent studies suggest that the use of CO 2 during pediatric esophagogastroduodenoscopy (EGD) with an unprotected airway is associated with transient elevations in exhaled CO 2 (end-tidal CO 2 , EtCO 2 ), raising safety concerns. One possible explanation for these events is eructation of insufflation gas from the stomach.

OBJECTIVES

To distinguish eructated versus absorbed CO 2 by sampling EtCO 2 from a protected airway with either laryngeal mask airway (LMA) or endotracheal tube (ETT), and to observe for changes in minute ventilation (MV) to exclude hypoventilation events.

METHODS

Double-blinded, randomized clinical trial of CO 2 versus air insufflation for EGD with airway protection by either LMA or ETT. Tidal volume, respiratory rate, MV, and EtCO 2 were automatically recorded every minute. Cohort demographics were described with descriptive characteristics. Variables including the percent of children with peak, transient EtCO 2 ≥ 60 mmHg were compared between groups.

RESULTS

One hundred ninety-five patients were enrolled for 200 procedures. Transient elevations in EtCO 2 of ≥60 mmHg were more common in the CO 2 group, compared to the air group (16% vs 5%, P = 0.02), but were mostly observed with LMA and less with ETT. Post-procedure pain was not different between groups, but flatulence was reported more with air insufflation ( P = 0.004).

CONCLUSION

Transient elevations in EtCO 2 occur more often with CO 2 than with air insufflation during pediatric EGD despite protecting the airway with an LMA or, to a lesser degree, with ETT. These elevations were not associated with changes in MV. Although no adverse clinical effects from CO 2 absorption were observed, these findings suggest that caution should be exercised when considering the use of CO 2 insufflation, especially since the observed benefits of using this gas were minimal.

Copyright © 2023 The Author(s). Published by Wolters Kluwer on behalf of European Society for Pediatric Gastroenterology, Hepatology, and Nutrition and North American Society for Pediatric Gastroenterology, Hepatology, and Nutrition.

Address: From the Division of Pediatric Gastroenterology, Hepatology and Nutrition, Department of Pediatrics, University of Nebraska Medical Center and Children's Hospital & Medical Center, Omaha, NE.; the Division of Pediatric Gastroenterology, Hepatology and Nutrition, Department of Pediatrics, University of Alabama at Birmingham, Birmingham, AL.; the Department of Biostatistics, School of Public Health, University of Nebraska Medical Center, Omaha, NE.; the Stead Family Department of Pediatrics, University of Iowa Hospitals and Clinics, Iowa City, IA.; the Department of Anesthesiology, Division of Pediatric Anesthesiology, University of Nebraska Medical Center, Omaha, NE.