Why a Diffusing Single-Molecule can be Detected in Few Minutes by a Large Capturing Bioelectronic Interface.

Eleonora Macchia, Liberato De Caro, Fabrizio Torricelli, Cinzia Di Franco, Giuseppe Felice Mangiatordi, Gaetano Scamarcio, Luisa Torsi

Journal: Advanced science (Weinheim, Baden-Wurttemberg, Germany) 2022;9(20):e2104381

PMID: 35522000

Abstract

Single-molecule detection at a nanometric interface in a femtomolar solution, can take weeks as the encounter rate between the diffusing molecule to be detected and the transducing nanodevice is negligibly small. On the other hand, several experiments prove that macroscopic label-free sensors based on field-effect-transistors, engaging micrometric or millimetric detecting interfaces are capable to assay a single-molecule in a large volume within few minutes. The present work demonstrates why at least a single molecule out of a few diffusing in a 100 µL volume has a high probability to hit a large capturing and detecting electronic interface. To this end, sensing data, measured with an electrolyte-gated FET whose gate is functionalized with 10 capturing anti-immunoglobulin G, are here provided along with a Brownian diffusion-based modeling. The EG-FET assays solutions down to some tens of zM in concentrations with volumes ranging from 25 µL to 1 mL in which the functionalized gates are incubated for times ranging from 30 s to 20 min. The high level of accordance between the experimental data and a model based on the Einstein's diffusion-theory proves how the single-molecule detection process at large-capturing interfaces is controlled by Brownian diffusion and yet is highly probable and fast.

© 2022 The Authors. Advanced Science published by Wiley-VCH GmbH.

Address: Faculty of Science and Engineering, Åbo Akademi University, Turku, 20500, Finland.; CSGI (Centre for Colloid and Surface Science), Bari, 70125, Italy.; Institute of Crystallography, National Research Council, via Amendola 122/O, Bari, 70126, Italy.; CSGI (Centre for Colloid and Surface Science), Bari, 70125, Italy.; Dipartimento Ingegneria dell'Informazione, Università degli Studi di Brescia, via Branze 38, Brescia, 25123, Italy.; CSGI (Centre for Colloid and Surface Science), Bari, 70125, Italy.; Dipartimento di Chimica, Università degli Studi di Bari "Aldo Moro,", Bari, 70125, Italy.; CNR, Istituto di Fotonica e Nanotecnologie, Sede di Bari, Bari, 70125, Italy.; CSGI (Centre for Colloid and Surface Science), Bari, 70125, Italy.; CNR, Istituto di Fotonica e Nanotecnologie, Sede di Bari, Bari, 70125, Italy.; Dipartimento Interateneo di Fisica "M. Merlin,", Università degli Studi di Bari "Aldo Moro,", Bari, 70125, Italy.; CSGI (Centre for Colloid and Surface Science), Bari, 70125, Italy.; Dipartimento di Chimica, Università degli Studi di Bari "Aldo Moro,", Bari, 70125, Italy.
Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.