Jerome R Lechien, Walter W Chan, Lee M Akst, Toshitaka Hoppo, Blair A Jobe, Carlos M Chiesa-Estomba, Vinciane Muls, Francois Bobin, Sven Saussez, Thomas L Carroll, Michael F Vaezi, Jonathan M Bock
Journal: Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery 2022;166(5):802-819
PMID: 34313507
OBJECTIVES
To review the normative data for acid, weakly acid, and nonacid proximal esophageal (PRE) and hypopharyngeal reflux (HRE) events in diagnosing laryngopharyngeal reflux (LPR) using ambulatory reflux monitoring.
DATA SOURCES
PubMed, Cochrane Library, and Scopus.
REVIEW METHODS
A literature search was conducted about the normative data for PRE and HRE on multichannel intraluminal impedance-pH monitoring (MII-pH), hypopharyngeal-esophageal MII-pH (HEMII-pH), or oropharyngeal pH monitoring using PICOTS (population, intervention, comparison, outcome, timing, and setting) and PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statements. Outcomes reviewed included device characteristics, impedance/pH sensor placements, study duration, number/average and percentiles of PRE or HRE occurrence, and the event characteristics (pH, composition, and position).
RESULTS
Of 154 identified studies, 18 met criteria for analysis, including 720 healthy individuals. HEMII-pH, MII-pH, and oropharyngeal pH monitoring were used in 7, 6, and 5 studies, respectively. The definition and inclusion/exclusion criteria of healthy individuals varied substantially across studies, with 6 studies considering only digestive symptoms to exclude potential LPR patients. Substantial heterogeneity across studies was noted, including impedance/pH sensor placements/configurations and definitions of composition (liquid, gas, mixed) and type (acid, weakly acid, nonacid) of PRE/HRE. The 95th percentile thresholds were 10 to 73 events for PRE, 0 to 10 events for HRE on HEMII-pH, and 40 to 128 for events with pH <6.0 on oropharyngeal pH monitoring. Most HREs were nonacid and occurred upright. The mean HRE among healthy individuals was 1.
CONCLUSION
The low number of studies and the heterogeneity in inclusion criteria, definitions, and characterization of PRE and HRE limit the establishment of consensual normative criteria for LPR on ambulatory reflux monitoring. Future large multicenter studies are needed.