Cushing's Disease: Assessment of Early Cardiovascular Hemodynamic Dysfunction With Impedance Cardiography.

Paweł Krzesiński, Beata Uziębło-Życzkowska, Agnieszka Jurek, Grzegorz Gielerak, Przemysław Witek, Grzegorz Zieliński, Anna Kazimierczak, Robert Wierzbowski, Małgorzata Banak

Journal: Frontiers in endocrinology 2022;12():751743

PMID: 34659130

Abstract

BACKGROUND

Cushing's disease is a rare condition associated with a high cardiovascular risk and hypercortisolemia-related hemodynamic dysfunction, the extent of which can be assessed with a noninvasive method, called impedance cardiography. The standard methods for hemodynamic assessment, such as echocardiography or ambulatory blood pressure monitoring may be insufficient to fully evaluate patients with Cushing's disease; therefore, impedance cardiography is being currently considered a new modality for assessing early hemodynamic dysfunction in this patient population. The use of impedance cardiography for diagnosis and treatment of Cushing's disease may serve as personalized noninvasive hemodynamic status assessment and provide a better insight into the pathophysiology of Cushing's disease. The purpose of this study was to assess the hemodynamic profile of Cushing's disease patients and compare it with that in the control group.

MATERIAL AND METHODS

This observational prospective clinical study aimed to compare 54 patients with Cushing's disease (mean age 41 years; with 64.8% of this population affected with arterial hypertension) and a matched 54-person control group (mean age 45 years; with 74.1% of this population affected with arterial hypertension). The hemodynamic parameters assessed with impedance cardiography included the stroke index (SI), cardiac index (CI), systemic vascular resistance index (SVRI), velocity index (VI), (ACI), Heather index (HI), and thoracic fluid content (TFC).

RESULTS

The Cushing's disease group was characterized by a higher diastolic blood pressure and a younger age than the control group (82.9 79.1 mmHg, p=0.045; and 41.1 44.9 years, p=0.035, respectively). Impedance cardiography parameters in the Cushing's disease group showed: lower values of SI (42.1 52.8 ml/m; p ≤ 0.0001), CI (2.99 3.64 l/min/m; p ≤ 0,0001), VI (42.9 52.1 1/1000/s; p=0.001), ACI (68.7 80.5 1/100/s; p=0,037), HI (13.1 15.2 Ohm/s; p=0.033), and TFC (25.5 27.7 1/kOhm; p=0.006) and a higher SVRI (2,515 1,893 dyn*s*cm*m; p ≤ 0.0001) than those in the control group.

CONCLUSIONS

Cushing's disease is associated with significantly greater vasoconstriction and left ventricular systolic dysfunction. An individual assessment with impedance cardiography may be useful in Cushing's disease patients in order to identify subclinical cardiovascular complications of chronic hypercortisolemia as potential therapeutic targets.

Copyright © 2021 Jurek, Krzesiński, Gielerak, Witek, Zieliński, Kazimierczak, Wierzbowski, Banak and Uziębło-Życzkowska.

Address: Department of Cardiology and Internal Diseases, Military Institute of Medicine, Warsaw, Poland.; Department of Internal Medicine, Endocrinology and Diabetes, Medical University of Warsaw, Warsaw, Poland.; Department of Neurosurgery, Military Institute of Medicine, Warsaw, Poland.
Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.