In vitro blood compatibility evaluation method: incubating while rotating hemodialyzers filled with fresh human blood.

Kinue Kamata, Yoshihiro Hatanaka, Hiromi Tanaka, Satoru Inoue, Yusuke Tokimizu, Sayuri Tanba, Yuki Kishikawa, Toshinori Koizumi

Journal: Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs 2021;24(3):412-416

PMID: 33200301

Abstract

One of the often-used methods for in vitro evaluation of the blood compatibility of hemodialysis membranes is the circulation of human blood through a miniaturized hemodialyzer. The use of a rather small amount of human blood in its evaluation is one advantage of this method. However, because it is manufactured by a different process than actual ones, a miniaturized hemodialyzer membrane cannot always preserve the properties of actual hemodialyzers. To address this problem, we established a new experimental method that uses a relatively small amount of human blood and actual dialyzers. In this method, a test hemodialyzer and a control hemodialyzer filled with human blood obtained from the same donor is slowly rotated to prevent spontaneous blood cell sedimentation for 4 h at 37 °C. By use of this method, we were able to compare blood compatibility between a polysulfone (PS) membrane and a vitamin E (VE)-bonded PS membrane in terms of their relative antithrombotic, antioxidative, and anti-inflammatory properties. Consistent with many previous reports, the results clearly showed that compared with the PS membrane, VE-bonded PS membrane is more blood compatible. These findings suggest that our method is applicable, at least to in vitro blood compatibility evaluation of PS type dialysis membranes.

© 2020. The Author(s).

Address: Medical Technology and Material Laboratory, Research and Business Development Division, Asahi Kasei Medical Co., LTD., 2-1, Samejima, Fuji-City, Shizuoka, 416-8501, Japan. [email protected].; Medical Technology and Material Laboratory, Research and Business Development Division, Asahi Kasei Medical Co., LTD., 2-1, Samejima, Fuji-City, Shizuoka, 416-8501, Japan. [email protected].; Medical Technology and Material Laboratory, Research and Business Development Division, Asahi Kasei Medical Co., LTD., 2-1, Samejima, Fuji-City, Shizuoka, 416-8501, Japan.
Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.