Estimates of Preterm Infants' Breastfeeding Transfer Volumes Are Not Reliably Accurate.

Sharon L Perrella, Kathryn Nancarrow, Alethea Rea, Kevin Murray, Donna T Geddes, Karen N Simmer

Journal: Advances in neonatal care : official journal of the National Association of Neonatal Nurses 2021;20(5):E93-E99

PMID: 32868595

Abstract

BACKGROUND

Adequate human milk nutrition is critical for infant growth and neurodevelopment; however, low milk transfer volumes are common when establishing preterm breastfeeding. Despite clinical assessments of milk transfer volumes at the breast being inaccurate, measurement of feed volume via test weighing is rarely carried out either routinely or in cases where infant weight gain is inadequate.

PURPOSE

To assess the accuracy of the Preterm Breastfeeding Assessment Tool (PBAT) in determining transfer volumes and examine factors associated with PBAT accuracy.

METHODS

Pre/postfeed weights were performed using electronic scales and PBAT scores recorded for 1186 breastfeeds in 60 preterm infants born less than 33/40 and 33 to 39/40 postmenstrual age. Measured milk intake volumes were converted to percent prescribed feed volume and compared with PBAT estimates of milk transfer.

RESULTS

The PBAT is accurate in identifying when no milk is transferred at the breast but not in estimating transfer of half or the full prescribed volume (accuracy 26% and 47%, respectively). Wide ranges of transfer volumes (11-75 mL) were observed within and between infants, and for 20% of breastfeeds, no milk was transferred. Preterm Breastfeeding Assessment Tool accuracy decreased with each 1-week increase in birth gestation (odds ratio = 0.82; 95% confidence interval, 0.71-0.94; P = .004).

IMPLICATIONS FOR PRACTICE

When establishing breastfeeding, test weighing facilitates adequate nutrition by guiding appropriate complementary feeding. For mothers breastfeeding several times per day in preparation for discharge home, test weighing may offer a useful tool for developing maternal confidence in assessing milk transfer. Preterm Breastfeeding Assessment Tool is inaccurate in assessing preterm infants' milk transfer volumes when breastfeeding.

IMPLICATIONS FOR RESEARCH

While studies have typically focused on medically stable infants, test weighing offers a useful tool to examine breastfeeding efficacy and inform nutritional management of preterm infants with complications such as chronic lung and cardiac disease.

Address: School of Molecular Sciences, Faculty of Science (Dr Perrella and Prof Geddes), School of Mathematics and Statistics, Faculty of Engineering and Mathematical Sciences (Dr Rea), School of Population and Global Health, Faculty of Health and Medical Sciences (Dr Murray), and Centre for Neonatal Research and Education, School of Paediatrics and Child Health, Faculty of Health and Medical Sciences (Prof Simmer), The University of Western Australia, Crawley, Western Australia; and Neonatology Clinical Care Unit, King Edward Memorial Hospital, Subiaco, Western Australia (Ms Nancarrow and Prof Simmer).