Wearing Compression Garment Enhances Central Hemodynamics? A Systematic Review and Meta-Analysis.

Daniel C W Lee, Ajmol Ali, Sinead Sheridan, Derwin K C Chan, Stephen H S Wong

Journal: Journal of strength and conditioning research 2022;36(8):2349-2359

PMID: 33065703

Abstract

Lee, DCW, Ali, A, Sheridan, S, Chan, DKC, and Wong, SHS. Wearing compression garment enhances central hemodynamics? a systematic review and meta-analysis. J Strength Cond Res 36(8): 2349-2359, 2022-Compression garments (CG) are believed to enhance exercise performance and recovery by improving central hemodynamic responses. However, evidence is inconclusive. We performed a systematic review and meta-analysis to determine the effect of wearing CG at rest or after a physiological challenge on central hemodynamic responses, including cardiac output, stroke volume (SV), heart rate (HR), systolic blood pressure, diastolic blood pressure (DBP), and systemic vascular resistance in healthy individuals. The English language searches of the electronic databases SPORTDiscus, MEDLINE, and Web of Science were conducted from November 2018-February 2019. The studies involved were limited to the following: (a) original articles; (b) randomized controlled trials; (c) monitoring of central hemodynamic responses (either at rest or after a physiological challenge: maximal exercise or orthostatic challenge); and (d) healthy individuals. Of the 786 studies identified, 12 were included in the systematic review and meta-analysis. Meta-analysis was performed by the restricted maximum likelihood method. The results indicated that the effect size (ES) of wearing CG on improving central hemodynamic responses was large overall (Hedges' g = 0.55) and was large in SV (Hedges' g = 1.09) and HR (Hedges' g = 0.65). Subgroup analysis showed that the ESs in "post-physiological challenge" was large in overall (Hedges' g = 0.98), SV (Hedges' g = 1.78), HR (Hedges' g = 1.10), and DBP (Hedges' g = 0.75). Their ESs in "at rest" were not significant in all central hemodynamic responses, apart from a significant medium ES observed in SV (Hedges' g = 0.44). Healthy individuals who wear CG have marked improvement in central hemodynamic responses, particularly after a physiological challenge. More pronounced effects of CG are observed in increasing SV and reducing HR.

Copyright © 2020 National Strength and Conditioning Association.

Address: Department of Sports Science and Physical Education, The Chinese University of Hong Kong, Hong Kong.; Elite Training Science and Technology Division, Hong Kong Sports Institute, Hong Kong.; School of Sport, Exercise, and Nutrition, Massey University, Auckland, New Zealand ; and.; Department of Early Childhood Education, Faculty of Education and Human Development, The Education University of Hong Kong, Hong Kong.
Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.