The effect of different interference fits on the primary fixation of a cementless femoral component during experimental testing.

Esther Sánchez, Christoph Schilling, Thomas M Grupp, Alexander Giurea, Caroline Wyers, Joop van den Bergh, Nico Verdonschot, Dennis Janssen

Journal: Journal of the mechanical behavior of biomedical materials 2021;113():104189

PMID: 33158789

Abstract

Cementless femoral total knee arthroplasty (TKA) components use a press-fit (referred to as interference fit) to achieve initial fixation. A higher interference fit could lead to a superior fixation, but it could also introduce more damage to the bone during implantation. The purpose of the current study was to investigate the effect of interference fit on the micromotions and gap opening/closing at the bone-implant interface. Experimental tests were performed in six pairs of cadaveric femurs implanted with femoral components using a low interference fit of 350 μm and a high interference fit of 700 μm. The specimens were subjected to the peak loads of gait and squat, based on the Orthoload dataset. Digital Image Correlation (DIC) was used to measure the micromotions and opening/closing in different regions of interest (ROIs). Two linear mixed-effect statistical models were created with micromotions and gap opening/closing as dependent variables. ROIs, loading conditions, and implant designs as independent variables, and cadaver specimens as random intercepts. The results revealed no significant difference between the two interference fit implants for micromotions (p = 0.837 for gait and p = 0.065 for squat), nor for the gap opening/closing (p = 0.748 for gait and p = 0.561 for squat). In contrast, significant differences were found between loading and most of the ROIs in both dependent variables (p < 0.0001). Additionally, no difference in bone deformation was found between low and high interference fit. Changing interference between either 350 μm or 700 μm did not affect the primary stability of a femoral TKA component. There could be an interference fit threshold beyond which fixation does not further improve.

Copyright © 2020 Elsevier Ltd. All rights reserved.

Address: Radboud University Medical Center, Radboud Institute for Health Sciences, Orthopaedic Research Lab, Nijmegen, the Netherlands. Electronic address: [email protected].; Aesculap AG, Research & Development, Tuttlingen, Germany.; Aesculap AG, Research & Development, Tuttlingen, Germany; Ludwig Maximilians University Munich, Department of Orthopaedic Surgery, Physical Medicine & Rehabilitation, Campus Grosshadern, Munich, Germany.; Medical University of Vienna, Department of Orthopedics, Vienna, Austria.; VieCuri Medical Center, Department of Internal Medicine, Venlo, the Netherlands; Maastricht University Medical Centre+ (MUMC+), Department of Internal Medicine, NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht, the Netherlands.; VieCuri Medical Center, Department of Internal Medicine, Venlo, the Netherlands; Maastricht University Medical Centre+ (MUMC+), Department of Internal Medicine, NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht, the Netherlands; Hasselt University, Biomedical Research Centre, Diepenbeek, Belgium.; Radboud University Medical Center, Radboud Institute for Health Sciences, Orthopaedic Research Lab, Nijmegen, the Netherlands; University of Twente, Laboratory for Biomechanical Engineering, Faculty of Engineering Technology, Enschede, the Netherlands.; Radboud University Medical Center, Radboud Institute for Health Sciences, Orthopaedic Research Lab, Nijmegen, the Netherlands.
Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.