Reliability of an injection-moulded two-piece zirconia implant with PEKK abutment after long-term thermo-mechanical loading.

Fei Zhang, Christoph Meyer Zur Heide, Jérome Chevalier, Jozef Vleugels, Bart Van Meerbeek, Christian Wesemann, Bernardo Camargo Dos Santos, Valter Sergo, Ralf-Joachim Kohal, Erik Adolfsson, Insa Herklotz, Benedikt C Spies

Journal: Journal of the mechanical behavior of biomedical materials 2021;110():103967

PMID: 32851978

Abstract

Zirconia implants are appreciated in some clinical indications in light of their aesthetic appearance and good biocompatibility. The aim of this work was to evaluate the performance of a newly developed two-piece zirconia/polyether ketone ketone (PEKK) implant-abutment combination after long-term cyclic loading in a hydrothermal environment, using a new protocol adapted from two available ISO standards. Sixteen implants (n = 8/group) were embedded according to ISO 14801 and divided into two groups: implants in the Observational Group (OG) were cyclically loaded for 60 days (98 N, 10 million loading cycles, 2 Hz) in 85 °C water in a chewing simulator, while non-loaded/non-aged implants (as-received) constituted the Control Group (CG). After 4.7 million loading cycles, one OG implant fractured in the chewing simulator. The surviving implants were compared to CG implants by X-ray diffraction (XRD) to investigate potential ageing as suggested by ISO 13356, but also μ-Raman spectroscopy, Focused-Ion-Beam - Scanning-Electron-Microscopy (FIB-SEM), and load-to-fracture. Ageing was shown to have limited influence on the evaluated zirconia implant, with increased monoclinic content after loading/ageing being to a shallow transformed zone of ~2 μm at the implant surface. However, OG implants showed a significantly decreased fracture load of 751 ± 231 N (CG: 995 ± 161 N; p = .046). These values enable clinical application, but the fact that one failure was recorded during cyclic fatigue along with the significant decrease in strength after cyclic loading/ageing suggest that there may be room for further optimization of especially the PEKK abutment. Furthermore, good agreement was observed between the fracture modes of the implant that failed during the cyclic fatigue experiment and the in vivo failure of one implant during pre-clinical trials, validating the interest of the in vitro protocol used in this work to check the reliability of zirconia implant.

Copyright © 2020 Elsevier Ltd. All rights reserved.

Address: KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT -Biomaterials Research Group & UZ Leuven (University Hospitals Leuven), Dentistry, Kapucijnenvoer 7 Blok a, B-3000, Leuven, Belgium; KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, B-3001, Heverlee, Belgium. Electronic address: [email protected].; Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, And Berlin Institute of Health, Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Aßmannshauser Str. 4-6, Berlin, Germany.; Université de Lyon, INSA-Lyon, UMR CNRS 5510 MATEIS, 20 Avenue Albert Einstein, 69621, Villeurbanne Cedex, France.; KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, B-3001, Heverlee, Belgium.; KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT -Biomaterials Research Group & UZ Leuven (University Hospitals Leuven), Dentistry, Kapucijnenvoer 7 Blok a, B-3000, Leuven, Belgium.; Engineering and Architecture Dept., University of Trieste, Italy; Faculty of Health Sciences, University of Macau, Macau SAR, China.; Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106, Freiburg, Germany.; RISE AB, Argongatan 30, 431 53, Mölndal, Sweden.

Link outs

Subscription / membership required

Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.