Intracoronary pressure gradient measurement in acute myocardial infarction patients with the no-reflow phenomenon during primary percutaneous coronary intervention.

Ming-Dong Gao, En-Yuan Zhang, Yuan-Ying Liu, Xiao-Wei Li, Jian-Yong Xiao, Gen-Yi Sun, Yin Liu

Journal: Chinese medical journal 2021;133(7):766-772

PMID: 32149760

Abstract

BACKGROUND

Various experimental and clinical studies have reported on coronary microcirculatory dysfunction ("no-reflow" phenomenon). Nevertheless, pathogenesis and effective treatment are yet to be fully elucidated. This study aimed to measure the intracoronary pressure gradient in the no-reflow artery during emergent percutaneous coronary intervention and explore the potential mechanism of no-reflow.

METHODS

From September 1st, 2018 to June 30th, 2019, intracoronary pressure in acute myocardial infarction patient was continuously measured by aspiration catheter from distal to proximal segment in the Department of Coronary Care Unit, Tianjin Chest Hospital, respectively in no-reflow arteries (no-reflow group) and arteries with thrombolysis in myocardial infarction-3 flow (control group). At least 12 cardiac cycles were consecutively recorded when the catheter was pulled back. The forward systolic pressure gradient was calculated as proximal systolic pressure minus distal systolic pressure. Comparison between groups was made using the Student t test, Mann-Whitney U-test or Chi-square test, as appropriate.

RESULTS

Intracoronary pressure in 33 no-reflow group and 26 in control group were measured. The intracoronary forward systolic pressure gradient was -1.3 (-4.8, 0.7) and 3.8 (0.8, 8.8) mmHg in no-reflow group and control group (Z = -3.989, P < 0.001), respectively, while the forward diastolic pressure gradient was -1.0 (-3.2, 0) and 4.6 (0, 16.5) mmHg in respective groups (Z = -3.851, P < 0.001). Moreover, the intracoronary forward pressure gradient showed significant difference between that before and after nicorandil medication (Z = -3.668, P < 0.001 in systolic pressure gradient and Z = -3.530, P < 0.001 in diastolic pressure gradient).

CONCLUSIONS

No reflow during emergent coronary revascularization is significantly associated with local hemodynamic abnormalities in the coronary arteries. Intracoronary nicorandil administration at the distal segment of a coronary artery with an aspiration catheter could improve the microcirculatory dysfunction and resume normal coronary pressure gradient.

CLINICAL TRIAL REGISTRATION

www.ClinicalTrials.gov (No. NCT03600259).

Address: Department of Coronary Care Unit, Tianjin Chest Hospital, Tianjin 300222, China.
Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.