A new Doppler signal enhancing agent for flow assessment in breast lesions.

H Madjar, H J Prömpeler, C Del Favero, B J Hackelöer, J B Llull

Journal: European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology 2001;12(2):123-30

PMID: 11118919

Abstract

OBJECTIVE

To determine the diagnostic performance of SonoVue (Bracco) in the enhancement of Doppler signals in breast lesions and in the improvement of diagnostic accuracy.

METHODS

This multicenter study included 220 patients undergoing investigations of parenchymal lesions, 40 of which had breast tumors. After a baseline Doppler examination, intravenous doses of 0.3, 0.6, 1.2 and 2.4 ml SonoVue were injected. Doppler signal quality before and after injection was compared. Off-site assessment of the global quality of Doppler signal and duration of clinical useful enhancement, as well as off-site and on-site evaluation of quality of color and spectral Doppler, were performed. On-site evaluation of diagnostic accuracy was also carried out. Safety assessments included monitoring of adverse events up to 24 h following the last injection of SonoVue.

RESULTS

On-site evaluations: baseline Doppler was conclusive in only 4/21 carcinomas and in 2/17 benign lesions. Enhanced Doppler improved differential diagnosis in 20/21 carcinomas and in 9/12 benign lesions. Time to color enhancement was 0.55 min for the lowest and 0.35 min for the highest dose. The total duration of enhancement was 3.47 min for the lowest and 5.62 min for the highest dose, respectively. Off-site assessment: SonoVue improved the quality of Doppler blood flow information both in parenchymal and focal lesions. Statistically significant changes from baseline in global quality of Doppler investigations were observed at all four SonoVue doses (P<0.05). The duration of clinically useful signal enhancement increased with doses and a significant dose relationship was obtained (P<0.001). Mild adverse events were observed in two patients only.

CONCLUSION

The results obtained from this study, following both off-site and on-site assessment, demonstrate that the administration of SonoVue to patients with focal breast lesions provides significant improvement over the baseline of Doppler signal quality and a clinically useful duration of signal enhancement, related to the dose. SonoVue was shown to be a safe and well-tolerated compound.

Address: Deutsche Klinik für Diagnostik (DKD), Aukammallee 33, 65191, Wiesbaden, Germany. [email protected]

Link outs

Subscription / membership required

Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.