Extra-abdominal dual-energy CT applications: a comprehensive overview.

Giuseppe Cicero, Giorgio Ascenti, Moritz H Albrecht, Alfredo Blandino, Marco Cavallaro, Tommaso D'Angelo, Maria Ludovica Carerj, Thomas J Vogl, Silvio Mazziotti

Journal: La Radiologia medica 2020;125(4):384-397

PMID: 31925704

Abstract

Unlike conventional computed tomography, dual-energy computed tomography is a relatively novel technique that exploits ionizing radiations at different energy levels. The separate radiation sets can be achieved through different technologies, such as dual source, dual layers or rapid switching voltage. Body tissue molecules vary for their specific atomic numbers and electron density, and the interaction with different sets of radiations results in different attenuations, allowing to their final distinction. In particular, iodine recognition and quantification have led to important information about intravenous contrast medium delivery within the body. Over the years, useful post-processing algorithms have also been validated for improving tissue characterization. For instance, contrast resolution improvement and metal artifact reduction can be obtained through virtual monoenergetic images, dose reduction by virtual non-contrast reconstructions and iodine distribution highlighting through iodine overlay maps. Beyond the evaluation of the abdominal organs, dual-energy computed tomography has also been successfully employed in other anatomical districts. Although lung perfusion is one of the most investigated, this evaluation has been extended to narrowly fields of application, such as musculoskeletal, head and neck, vascular and cardiac. The potential pool of information provided by dual-energy technology is already wide and not completely explored, yet. Therefore, its performance continues to raise increasing interest from both radiologists and clinicians.

Address: Section of Radiological Sciences, Department of Biomedical Sciences and Morphological and Functional Imaging, University of Messina, Policlinico "G. Martino" Via Consolare Valeria 1, 98100, Messina, Italy. [email protected].; Section of Radiological Sciences, Department of Biomedical Sciences and Morphological and Functional Imaging, University of Messina, Policlinico "G. Martino" Via Consolare Valeria 1, 98100, Messina, Italy.; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany.

Link outs

Subscription / membership required

Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.