Speckle tracking quantification of lung sliding for the diagnosis of pneumothorax: a multicentric observational study.

Gary Duclos, Xavier Bobbia, Thibaut Markarian, Laurent Muller, Camille Cheyssac, Sarah Castillon, Noémie Resseguier, Alain Boussuges, Giovanni Volpicelli, Marc Leone, Laurent Zieleskiewicz

Journal: Intensive care medicine 2020;45(9):1212-1218

PMID: 31359081

Abstract

PURPOSE

Lung ultrasound is used for the diagnosis of pneumothorax, based on lung sliding abolition which is a qualitative and operator-dependent assessment. Speckle tracking allows the quantification of structure deformation over time by analysing acoustic markers. We aimed to test the ability of speckle tracking technology to quantify lung sliding in a selected cohort of patients and to observe how the technology may help the process of pneumothorax diagnosis.

METHODS

We performed retrospectively a pleural speckle tracking analysis on ultrasound loops from patients with pneumothorax. We compared the values measured by two observers from pneumothorax side with contralateral normal lung side. The receiver operating characteristic (ROC) curve was constructed to evaluate the performance of maximal pleural strain to detect the lung sliding abolition. Diagnosis performance and time to diagnosis between B-Mode and speckle tracking technology were compared from a third blinded observer.

RESULTS

We analysed 104 ultrasound loops from 52 patients. The area under the ROC curve of the maximal pleural strain value to identify lung sliding abolition was 1.00 [95%CI 1.00; 1.00]. Specificity was 100% [95%CI 93%; 100%] and sensitivity was 100% [95%CI 93%; 100%] with the best cut-off of 4%. Over 104 ultrasound loops, the blinded observer made two errors with B-Mode and none with speckle tracking. The median diagnosis time was 3 [2-5] seconds for B-Mode versus 2 [1-2] seconds for speckle tracking (p = 0.001).

CONCLUSION

Speckle tracking technology allows lung sliding quantification and detection of lung sliding abolition in case of pneumothorax on selected ultrasound loops.

Address: Department of Anesthesiology and Intensive Care Medicine, Aix-Marseille University, Assistance Publique Hôpitaux de Marseille, Hôpital Nord, Marseille, France. [email protected].; Department of Anesthesiology, Emergency and Critical Care Medicine, Intensive Care Unit, Nîmes University Hospital, 30029, Nîmes, France.; Department of Emergency Medicine and Intensive Care, Aix-Marseille University, Assistance Publique Hôpitaux de Marseille, Timone University Hospital, Marseille, France.; Department of Anesthesiology and Intensive Care Medicine, Aix-Marseille University, Assistance Publique Hôpitaux de Marseille, Hôpital Nord, Marseille, France.; Support Unit for Clinical Research and Economic Evaluation, Assistance Publique-Hôpitaux de Marseille, Marseille, France.; Service des Explorations fonctionnelles respiratoires, CHU Nord, Pôle thoracique et cardio-vasculaire, Assistance publique des Hôpitaux de Marseille, Marseille, France.; Center for Cardiovascular and Nutrition Research (C2VN), Aix Marseille Université, INSERM, INRA, Marseille, France.; Department of Emergency Medicine, San Luigi Gonzaga University Hospital, Turin, Italy.; Department of Anesthesiology and Intensive Care Medicine, Aix-Marseille University, Assistance Publique Hôpitaux de Marseille, Hôpital Nord, Marseille, France. [email protected].; Center for Cardiovascular and Nutrition Research (C2VN), Aix Marseille Université, INSERM, INRA, Marseille, France. [email protected].