Differentiating supraclavicular from gluteal adipose tissue based on simultaneous PDFF and T * mapping using a 20-echo gradient-echo acquisition.

Daniela Franz, Maximilian N Diefenbach, Franziska Treibel, Dominik Weidlich, Jan Syväri, Stefan Ruschke, Mingming Wu, Christina Holzapfel, Theresa Drabsch, Thomas Baum, Holger Eggers, Ernst J Rummeny, Hans Hauner, Dimitrios C Karampinos

Journal: Journal of magnetic resonance imaging : JMRI 2020;50(2):424-434

PMID: 30684282

Abstract

BACKGROUND

Adipose tissue (AT) can be classified into white and brown/beige subtypes. Chemical shift encoding-based water-fat MRI-techniques allowing simultaneous mapping of proton density fat fraction (PDFF) and T * result in a lower PDFF and a shorter T * in brown compared with white AT. However, AT T * values vary widely in the literature and are primarily based on 6-echo data. Increasing the number of echoes in a multiecho gradient-echo acquisition is expected to increase the precision of AT T * mapping.

PURPOSE

1) To mitigate issues of current T *-measurement techniques through experimental design, and 2) to investigate gluteal and supraclavicular AT T * and PDFF and their relationship using a 20-echo gradient-echo acquisition.

STUDY TYPE

Prospective.

SUBJECTS

Twenty-one healthy subjects.

FIELD STRENGTH/SEQUENCE ASSESSMENT

First, a ground truth signal evolution was simulated from a single-T * water-fat model. Second, a time-interleaved 20-echo gradient-echo sequence with monopolar gradients of neck and abdomen/pelvis at 3 T was performed in vivo to determine supraclavicular and gluteal PDFF and T *. Complex-based water-fat separation was performed for the first 6 echoes and the full 20 echoes. AT depots were segmented.

STATISTICAL TESTS

Mann-Whitney test, Wilcoxon signed-rank test and simple linear regression analysis.

RESULTS

Both PDFF and T * differed significantly between supraclavicular and gluteal AT with 6 and 20 echoes (PDFF: P < 0.0001 each, T *: P = 0.03 / P < 0.0001 for 6/20 echoes). 6-echo T * demonstrated higher standard deviations and broader ranges than 20-echo T *. Regression analyses revealed a strong relationship between PDFF and T * values per AT compartment (R = 0.63 supraclavicular, R = 0.86 gluteal, P < 0.0001 each).

DATA CONCLUSION

The present findings suggest that an increase in the number of sampled echoes beyond 6 does not affect AT PDFF quantification, whereas AT T * is considerably affected. Thus, a 20-echo gradient-echo acquisition enables a multiparametric analysis of both AT PDFF and T * and may therefore improve MR-based differentiation between white and brown fat.

LEVEL OF EVIDENCE

2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:424-434.

© 2019 The Authors. Journal of Magnetic Resonance Imaging published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

Address: Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.; Institute for Nutritional Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.; Department of Diagnostic and Interventional Neuroradiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.; Philips Research Laboratory, Hamburg, Germany.