Electrochemically Exfoliated High-Quality 2H-MoS for Multiflake Thin Film Flexible Biosensors.

Panpan Zhang, Sheng Yang, Roberto Pineda-Gómez, Bergoi Ibarlucea, Ji Ma, Martin R Lohe, Teuku Fawzul Akbar, Larysa Baraban, Gianaurelio Cuniberti, Xinliang Feng

Journal: Small (Weinheim an der Bergstrasse, Germany) 2020;15(23):e1901265

PMID: 31034144

Abstract

2D molybdenum disulfide (MoS ) gives a new inspiration for the field of nanoelectronics, photovoltaics, and sensorics. However, the most common processing technology, e.g., liquid-phase based scalable exfoliation used for device fabrication, leads to the number of shortcomings that impede their large area production and integration. Major challenges are associated with the small size and low concentration of MoS flakes, as well as insufficient control over their physical properties, e.g., internal heterogeneity of the metallic and semiconducting phases. Here it is demonstrated that large semiconducting MoS sheets (with dimensions up to 50 µm) can be obtained by a facile cathodic exfoliation approach in nonaqueous electrolyte. The synthetic process avoids surface oxidation thus preserving the MoS sheets with intact crystalline structure. It is further demonstrated at the proof-of-concept level, a solution-processed large area (60 × 60 µm) flexible Ebola biosensor, based on a MoS thin film (6 µm thickness) fabricated via restacking of the multiple flakes on the polyimide substrate. The experimental results reveal a low detection limit (in femtomolar-picomolar range) of the fabricated sensor devices. The presented exfoliation method opens up new opportunities for fabrication of large arrays of multifunctional biomedical devices based on novel 2D materials.

© 2019 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Address: Chair for Molecular Functional Materials, Department of Chemistry and Food Chemistry, School of Science, Technische Universität Dresden, Mommsenstr. 4, 01069, Dresden, Germany.; Center for Advancing Electronics Dresden (cfaed), Technische Universität Dresden, 01062, Dresden, Germany.; Max Bergman Center of Biomaterials Dresden and Institute for Materials Science, Technische Universität Dresden, 01062, Dresden, Germany.

Link outs

Subscription / membership required

Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.