Diagnostic accuracy of DW MR imaging in the differentiation of chordomas and chondrosarcomas of the skull base: A 3.0-T MRI study of 105 cases.

Thomas Welzel, Eva Meyerhof, Matthias Uhl, Kristin Huang, Andreas von Deimling, Klaus Herfarth, Jürgen Debus

Journal: European journal of radiology 2018;105():119-124

PMID: 30017267

Abstract

PURPOSE

To determine the diagnostic accuracy of DW MR imaging with apparent diffusion coefficient (ADC) mapping for the distinction of skull base chordoma from skull base chondrosarcoma.

PATIENTS AND METHODS

From October 2009 to April 2014, 105 consecutive patients (chordomas (n = 70), and chondrosarcomas (n = 35) who were planned to receive proton or heavy-ion beam therapy underwent DW MR imaging on a 3.0 T. MR images were assessed by means of consensus of three experienced radiologists who were blinded to pathologic and clinical information. ADC values (mean, minimum, maximum, and normalized) of the solid tumor component were evaluated. Group means and cut-off points were established to separate skull base chordoma from skull base chondrosarcoma, and statistical significances were calculated by Student's t or Mann-Whitney-U tests, and receiver operating characteristic (ROC) curve analyses. The prospective study was approved by the institutional ethics committee.

RESULTS

For solid tumor component, there were higher mean, minimum, maximum, and normalized ADC values in chondrosarcomas compared with those in chordomas (all p < 0.001). ROC analysis revealed areas under the curve for mean, minimum, maximum, and normalized ADC values between 0.79 and 0.93. The mean ADC value of the solid tumor components had the best AUC, with a cut-off point of 1585 × 10(-6) mm (2)/s and sensitivity and specificity of 94.3% and 98.6%, respectively.

CONCLUSION

Skull base Chondrosarcomas generally have higher mean, minimum, maximum, and normalized ADC values than skull base chordomas, with the mean ADC value of the solid tumor component offering the highest accuracy for characterization.

Copyright © 2018 Elsevier B.V. All rights reserved.

Address: Department of Radiooncology, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany. Electronic address: [email protected].; Department of Radiooncology, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany.; Department of Radiooncology, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; Heidelberg Ion Therapy Center (HIT), Im Neuenheimer Feld 450, 69120 Heidelberg, Germany.; Department of Neuropathology, University of Heidelberg, Im Neuenheimer Feld 672, 69120 Heidelberg, Germany.; Department of Radiooncology, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; Heidelberg Ion Therapy Center (HIT), Im Neuenheimer Feld 450, 69120 Heidelberg, Germany; German Cancer Research Center (DKFZ) and German Cancer Consortium (DKTK), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany.
Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support: