Andrea Soria Gondek, Lucia Riaza, Daniel Cuadras, Xavier Tarrado Castellarnau, Lucal Krauel
Journal: Journal of pediatric surgery 2018;53(4):599-604
PMID: 29150367
BACKGROUND/PURPOSE
To identify factors that dim the efficacy of ultrasound guided saline enema (USGSE) and to design a mathematical model for predicting the probability of success of USGSE.
METHODS
Retrospective review of patients admitted with the diagnosis of ileocolic intussusception from 2009 to 2014. Demographics, clinical and sonographic data were reviewed.
RESULTS
116 first episodes of ileocolic intussusceptions. 109 USGSE attempts were analyzed. Composite reduction rate was 77%. A significant relationship was found between initial location of the intussusception, free peritoneal fluid (OR=0.329, 95% CI: 0.124-0.875), negative Doppler signal and sonographic signs of intestinal occlusion and unsuccessful USGSE. Initial location beyond the splenic angle was an independent risk factor for USGSE failure (OR=0.053, 95% CI: 0.005-0.534). A predictive model based on onset of symptoms, free peritoneal fluid and intussusception location was a reliable tool for prediction (AUC 0.63, 95% CI: 0.53-0.817). Assuming that a patient with less than 75.3% chance of USGSE success is going to fail, we would identify more than 80.9% of the real failures.
CONCLUSIONS
This predictive model could be a filter selection for the patients at risk of USGSE failure and therefore candidates to further imaging investigations or referral to a surgical unit.
LEVEL OF EVIDENCE
III.