Diagnostic Accuracy of a Novel Chromogenic Direct Thrombin Inhibitor Assay: Clinical Experiences for Dabigatran Monitoring.

Sven Poli, Florian Härtig, Charlotte Spencer, Matthias Ebner, Ingvild Birschmann, Joachim Kuhn, Susanne Faix, Ulf Ziemann, Hans-Ulrich Häring, Rainer Lehmann, Andreas Peter, Sebastian Hörber

Journal: Thrombosis and haemostasis 2019;117(12):2369-2375

PMID: 29212124

Abstract

Background Direct oral anticoagulants (DOACs) are increasingly replacing vitamin K antagonists (VKA) for clinical indications requiring long-term oral anticoagulation. In contrast to VKA, treatment with DOAC including dabigatran—the only direct thrombin inhibitor amongst them—does not require therapeutic drug monitoring. However, in case of treatment complications (e.g., major haemorrhage) and conditions requiring urgent surgery or thrombolytic therapy, information about actual DOAC plasma levels is needed to guide treatment decisions. Due to short reagent stability, limited accuracy at low dabigatran levels and high heparin sensitivity, the applicability of the widely used Hemoclot thrombin inhibitor (HTI) coagulation assay is limited in the emergency setting. Methods Dabigatran concentrations of 288 citrated plasma samples taken from 48 dabigatran-treated patients with drug concentrations of up to 300 ng/mL were measured with the chromogenic anti-IIa Biophen direct thrombin inhibitor (BDTI) assay and results compared with HTI using ultra performance liquid chromatography—tandem mass spectrometry as the reference method for measuring dabigatran plasma concentrations. Results BDTI results showed a very strong correlation with dabigatran concentrations (r = 0.965, p < 0.0001) as well as a low intra- and inter-assay variation of <5%. Compared with HTI, BDTI provides an improved on-board reagent stability of 72 hours, rapid turnaround times comparable to routine coagulation assays, high accuracy at low drug levels and reduced heparin sensitivity. Conclusion The BDTI is an ideal coagulation assay for the around-the-clock determination of dabigatran plasma levels in clinical routine including emergency situations.

Address: Department of Neurology and Stroke, Hertie Institute for Clinical Brain Research, University of Tübingen, Tübingen, Germany.; Department of Internal Medicine and Cardiology, Charité University Medicine Berlin - Campus Virchow Klinikum, Berlin, Germany.; Institute for Laboratory and Transfusion Medicine, Heart and Diabetes Center, Bad Oeynhausen, Ruhr University, Bochum, Germany.; Division of Endocrinology, Diabetology, Vascular Medicine, Nephrology and Clinical Chemistry, Department of Internal Medicine, University of Tübingen, Germany.; Institute for Diabetes Research and Metabolic Diseases of the Helmholtz Center Munich at the University of Tübingen, Tübingen, Germany.; German Center for Diabetes Research (DZD), München-Neuherberg, Germany.
Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.