Evaluation and control of microbial and chemical contamination in dialysis water plants of Italian nephrology wards.

M Totaro, B Casini, P Valentini, M Miccoli, S Giorgi, A Porretta, G Privitera, P L Lopalco, A Baggiani

Journal: The Journal of hospital infection 2018;97(2):169-174

PMID: 28546028

Abstract

BACKGROUND

Patients receiving haemodialysis are exposed to a large volume of dialysis fluid. The Italian Society of Nephrology (ISN) has published guidelines and microbial quality standards on dialysis water (DW) and solutions to ensure patient safety.

AIM

To identify microbial and chemical hazards, and evaluate the quality of disinfection treatment in DW plants.

METHODS

In 2015 and 2016, water networks and DW plants (closed loop and online monitors) of nine dialysis wards of Italian hospitals, hosting 162 dialysis beds overall, were sampled on a monthly basis to determine the parameters provided by ISN guidelines. Chlorinated drinking water was desalinated by reverse osmosis and distributed to the closed loop which feeds all online monitors. Disinfection with peracetic acid was performed in all DW plants on a monthly basis.

FINDINGS

Over the 24-month study period, seven out of nine DW plants (78%) recorded negative results for all investigated parameters. Closed loop contamination with Burkholderia cepacia was detected in a DW plant from January 2015 to March 2015. Pseudomonas aeruginosa was isolated from March 2016 to May 2016 in the closed loop of another DW plant. These microbial contaminations were eradicated by shock disinfection with sodium hypochlorite and peracetic acid, followed by water flushing.

CONCLUSION

These results highlight the importance of chemical and physical methods of DW disinfection. The maintenance of control measures in water plants hosted in dialysis wards ensures a microbial risk reduction for all dialysis patients.

Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

Address: Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy.; Department of Clinical and Experimental Medicine, University of Pisa, Pisa, Italy.; Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy. Electronic address: [email protected].