F Alan Barber, David B Spenciner, Samir Bhattacharyya, Larry E Miller
Journal: Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association 2017;33(3):683-689
PMID: 27998641
PURPOSE
To determine the degradation and performance outcomes of poly(lactide-co-glycolide)/β-tricalcium phosphate (PLGA/β-TCP) implants.
METHODS
A MEDLINE and Embase search for randomized or nonrandomized controlled studies and prospective or retrospective case series that used biocomposite interference screws or suture anchors composed of PLGA/β-TCP was performed. Main outcomes included volume of implant resorption and incidence of osteoconductivity at implant sites, imaging findings, adverse events, and the frequency of reoperations.
RESULTS
A total of 13 studies representing 668 patients with either knee or shoulder implants were included. Median follow-up was 28 months (range: 12-37 months). Biocomposite implants lost 88% of their original volume during follow-up. Osteoconductivity at the implant site was identified in 63% of cases. Adverse events included tunnel widening (3%), effusion (5%), and cyst formation (4%). Synovitis was not reported.
CONCLUSIONS
Biocomposite interference screws or suture anchors composed of PLGA/β-TCP almost fully absorb over 3 years while promoting osteoconductivity with few reported adverse events.
LEVEL OF EVIDENCE
Level IV, systematic review of Level I-IV studies.