Adenoma detection with blue-water infusion colonoscopy: a randomized trial.

Denis Péré-Vergé, Claire Billioud, Elsa Thimonier, Karine Stroeymeyt-Martin, Benjamin Hamel, Emmanuelle Graillot, Claire Cruiziat, Olivia Scalone, Marc O'Brien, Philippe Brulet, Jean-Christophe Souquet, Jean-Marc Phelip, Laurent Poincloux, Stéphanie Poupon-Bourdy, Angélique Denis, Laurent Magaud, Thierry Ponchon, Mathieu Pioche, Sylvaine Chalumeau, Olivier Rouquette, Sandrine Touzet, Fabien Petit-Laurent, Gwenaelle Tourlonias, Audrey Pasquion, Jérôme Rivory, Guillermo Aguero Garcete, Julien Scanzi, Adriane Lesne, Christine Chambon-Augoyard, Driffa Moussata, Florence Leger-Nguyen, Stéphane Degeorges, Marion Chauvenet, Thierry Fontanges, Sandrine Baubet

Journal: Endoscopy 2018;49(8):765-775

PMID: 28399611

Abstract

UNLABELLED

 Colonoscopy is currently the reference method to detect colorectal neoplasia, yet some adenomas remain undetected. The water infusion technique and dying with indigo carmine has shown interesting results for reducing this miss rate. The aim of this study was to compare the adenoma detection rate (adenoma and adenocarcinoma; ADR) and the mean number of adenomas per patient (MAP) for blue-water infusion colonoscopy (BWIC) versus standard colonoscopy.  We performed a multicenter, randomized controlled trial in eight units, including patients with a validated indication for colonoscopy (symptoms, familial or personal history, fecal occult blood test positive). Consenting patients were randomized 1:1 to BWIC or standard colonoscopy. All colonoscopies were performed by experienced colonoscopists. All colonoscopy quality indicators were prospectively recorded.  Among the 1065 patients included, colonoscopies were performed completely for 983 patients (514 men; mean age 59.1). The ADR was not significantly different between the groups; 40.4 % in the BWIC group versus 37.5 % in the standard colonoscopy group (odds ratio [OR] 1.13; 95 % confidence interval [CI] 0.87 - 1.48;  = 0.35). MAP was significantly greater in the BWIC group (0.79) than in the standard colonoscopy group (0.64;  = 0.005). For advanced adenomas, the results were 50 (10.2 %) and 36 (7.3 %), respectively ( = 0.10). The cecal intubation rate was not different but the time to cecal intubation was significantly longer in BWIC group (9.9 versus 6.2 minutes;  < 0.001).  Despite the higher MAP with BWIC, the routine use of BWIC does not translate to a higher ADR. Whether increased detection ultimately results in a lower rate of interval carcinoma is not yet known.

CLINICAL TRIALS REGISTRATION

EudraCT 2012-A00548 - 35; NCT01937429.

© Georg Thieme Verlag KG Stuttgart · New York.

Address: Hepatogastroenterology Department, Hôpital Edouard Herriot, Hospices Civils de Lyon, France.; Lyon 1 University Claude Bernard, Lyon, France.; Hepatogastroenterology Department, University Hospital d'Estaing, Clermont-Ferrand, France.; Hospices Civils de Lyon, pôle Information médicale Evaluation Recherche, and Université de Lyon, EA 7425 Health Services and Performance Research (HESPER), Lyon, France.; Hepatogastroenterology Department, Nord Ouest Hospital, Villefranche-sur-Saône, France.; Hepatogastroenterology Department, University Hospital Croix Rousse, Lyon, France.; Hepatogastroenterology Department, University Hospital Saint-Etienne, Saint-Priest en Jarez, France.; Hepatogastroenterology Department, St Joseph St Luc Hospital, Lyon, France.; Hepatogastroenterology Department, University Hospital Lyon Sud, Pierre-Bénite, France.; Hepatogastroenterology Department, Public Hospital Bourgoin-Jallieu, France.; INSERM U1032, LabTau, Lyon, France.
Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.