A strain-mediated corrosion model for bioabsorbable metallic stents.

E Galvin, D O'Brien, C Cummins, B J Mac Donald, C Lally

Journal: Acta biomaterialia 2018;55():505-517

PMID: 28433790

Abstract

UNLABELLED

This paper presents a strain-mediated phenomenological corrosion model, based on the discrete finite element modelling method which was developed for use with the ANSYS Implicit finite element code. The corrosion model was calibrated from experimental data and used to simulate the corrosion performance of a WE43 magnesium alloy stent. The model was found to be capable of predicting the experimentally observed plastic strain-mediated mass loss profile. The non-linear plastic strain model, extrapolated from the experimental data, was also found to adequately capture the corrosion-induced reduction in the radial stiffness of the stent over time. The model developed will help direct future design efforts towards the minimisation of plastic strain during device manufacture, deployment and in-service, in order to reduce corrosion rates and prolong the mechanical integrity of magnesium devices.

STATEMENT OF SIGNIFICANCE

The need for corrosion models that explore the interaction of strain with corrosion damage has been recognised as one of the current challenges in degradable material modelling (Gastaldi et al., 2011). A finite element based plastic strain-mediated phenomenological corrosion model was developed in this work and was calibrated based on the results of the corrosion experiments. It was found to be capable of predicting the experimentally observed plastic strain-mediated mass loss profile and the corrosion-induced reduction in the radial stiffness of the stent over time. To the author's knowledge, the results presented here represent the first experimental calibration of a plastic strain-mediated corrosion model of a corroding magnesium stent.

Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Address: School of Mechanical and Manufacturing Engineering, Dublin City University, Dublin 9, Ireland. Electronic address: [email protected].; School of Mechanical and Manufacturing Engineering, Dublin City University, Dublin 9, Ireland.; Vasorum Ltd., 2012 Orchard Avenue, Citywest Campus, Dublin 24, Ireland.; Department of Mechanical and Manufacturing Engineering, School of Engineering and Trinity Centre For Bioengineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, The University of Dublin, Dublin 2, Ireland. Electronic address: [email protected].

Link outs

Free resources

Subscription / membership required

Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.