Red blood cell concentrates treated with the amustaline (S-303) pathogen reduction system and stored for 35 days retain post-transfusion viability: results of a two-centre study.

J A Cancelas, J L Gottschall, N Rugg, S Graminske, M A Schott, A North, N Huang, N Mufti, A Erickson, S Rico, L Corash

Journal: Vox sanguinis 2017;112(3):210-218

PMID: 28220519

Abstract

BACKGROUND AND OBJECTIVES

Pathogen reduction technology using amustaline (S-303) was developed to reduce the risk of transfusion-transmitted infection and adverse effects of residual leucocytes. In this study, the viability of red blood cells (RBCs) prepared with a second-generation process and stored for 35 days was evaluated in two different blood centres.

MATERIALS AND METHODS

In a single-blind, randomized, controlled, two-period crossover study (n = 42 healthy subjects), amustaline-treated (Test) or Control RBCs were prepared in random sequence and stored for 35 days. On day 35, an aliquot of Cr/ Tc radiolabeled RBCs was transfused. In a subgroup of 26 evaluable subjects, 24-h RBC post-transfusion recovery, mean life span, median life span (T ) and life span area under the curve (AUC) were analysed.

RESULTS

The mean 24-h post-transfusion recovery of Test and Control RBCs was comparable (83·2 ± 5·2 and 84·9 ± 5·9%, respectively; P = 0·06) and consistent with the US Food and Drug Administration (FDA) criteria for acceptable RBC viability. There were differences in the T between Test and Control RBCs (33·5 and 39·7 days, respectively; P < 0·001), however, these were within published reference ranges of 28-35 days. The AUC (per cent surviving × days) for Test and Control RBCs was similar (22·6 and 23·1 per cent surviving cells × days, respectively; P > 0·05). Following infusion of Test RBCs, there were no clinically relevant abnormal laboratory values or adverse events.

CONCLUSION

RBCs prepared using amustaline pathogen reduction meet the FDA criteria for post-transfusion recovery and are metabolically and physiologically appropriate for transfusion following 35 days of storage.

© 2017 The Authors. Vox Sanguinis published by John Wiley & Sons Ltd on behalf of International Society of Blood Transfusion.

Address: Hoxworth Blood Center, Cincinnati, OH, USA.; BloodCenter of Wisconsin, Milwaukee, WI, USA.; Cerus Corporation, Concord, CA, USA.

Link outs

Free resources

Other Literature Sources:

Subscription / membership required

Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.