Early results using a biodegradable magnesium screw for modified chevron osteotomies.

Christian Plaass, Sarah Ettinger, Lena Sonnow, Soeren Koenneker, Yvonne Noll, Andreas Weizbauer, Janin Reifenrath, Leif Claassen, Kiriakos Daniilidis, Christina Stukenborg-Colsman, Henning Windhagen

Journal: Journal of orthopaedic research : official publication of the Orthopaedic Research Society 2017;34(12):2207-2214

PMID: 28005292

Abstract

This is the first larger study analyzing the use of magnesium-based screws for fixation of modified Chevron osteotomies in hallux valgus surgery. Forty-four patients (45 feet) were included in this prospective study. A modified Chevron osteotomy was performed on every patient and a magnesium screw used for fixation. The mean clinical follow up was 21.4 weeks. The mean age of the patients was 45.5 years. Forty patients could be provided with the implant, in four patients the surgeon decided to change to a standard metallic implant. The AOFAS, FAAM and pain NRS-scale improved markedly. The hallux valgus angle, intermetatarsal angle and sesamoid position improved significantly. Seven patients showed dorsal subluxation, rotation or medial shifting of the metatarsal heads within the first 3 months. One of these patients was revised, in all others the findings were considered clinically not significant or the patients refused revision. This study shows the feasibility of using magnesium screws in hallux valgus-surgery. Surgeons starting with the use of these implants should be aware of the proper handling of these implants and should know about corrosion effects during healing and its radiographic appearance. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:2207-2214, 2016.

© 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Address: Department of Orthopedic Surgery, Hannover Medical School, Anna-von-Borries Strasse 1-7, 30625 Hannover, Germany.; Institute for Radiology, Hannover Medical School, Carl-Neuberg Strasse 1, 30625, Hannover, Germany.; Department for Plastic, Aesthetic, Hand and Reconstructive Surgery, Hannover Medical School, Carl-Neuberg-Strasse 1, 30625, Hannover, Germany.; Laboratory of Biomechanics and Biomaterials, Department of Orthopedic Surgery, Hannover Medical School, Anna-von-Borries-Strasse 1-7, Hannover, Germany.; CrossBIT, Centre for Biocompatibility and Implant-Immunology, Department of Orthopedic Surgery, Hannover Medical School, Carl-Neuberg-Strasse 1-7, 30625, Hannover, Germany.

Link outs

Subscription / membership required

Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.