Influence of geometry and materials on the axial and torsional strength of the head-neck taper junction in modular hip replacements: A finite element study.

Khosro Fallahnezhad, Hamidreza Farhoudi, Reza H Oskouei, Mark Taylor

Journal: Journal of the mechanical behavior of biomedical materials 2017;60():118-126

PMID: 26807768

Abstract

The assembly force is important in establishing the mechanical environment at the head-neck taper junction of modular hip replacements. Previous experimental results of the assembled taper junctions with different material combinations (Co-28Cr-6Mo and Ti-6Al-4V) reported similar axial strengths (pull-off loads), but lower torsional strengths (twist-off moments) for the CoCr/CoCr junction. However, mechanics of the junction and the strength behaviour have not been understood yet. A three dimensional finite element model of an isolated femoral head-neck junction was developed to explore the assembly and disassembly procedures, particularly the axial and torsional strengths for different material combinations and geometries. Under the same assembly load, the contacting length between the CoCr head and titanium neck was greater than that of in CoCr/CoCr. The contact length in the titanium neck was more sensitive to the assembly force when compared to the CoCr neck. For instance, with increasing the assembly force from 1890 to 3700N, the contact length increased by 88% for CoCr/Ti and 59% for CoCr/CoCr junctions. The torsional strength of the junction was related to the lateral deformation of the neck material due to the applied moment. The angular mismatch existing between the head and neck components was found to play the main role in the torsional strength of the junction. The smaller mismatch angle the higher torsional strength. It is suggested to consider reducing the mismatch angle, particularly in CoCr/CoCr junctions, and ensure a sufficiently high assembly force is applied by impaction for this combination.

Copyright © 2016 Elsevier Ltd. All rights reserved.

Address: Discipline of Mechanical Engineering, School of Computer Science, Engineering and Mathematics, Flinders University, Adelaide, Australia. Electronic address: [email protected].; Discipline of Mechanical Engineering, School of Computer Science, Engineering and Mathematics, Flinders University, Adelaide, Australia. Electronic address: [email protected].; The Medical Device Research Institute, School of Computer Science, Engineering and Mathematics, Flinders University, Adelaide, Australia. Electronic address: [email protected].; The Medical Device Research Institute, School of Computer Science, Engineering and Mathematics, Flinders University, Adelaide, Australia. Electronic address: [email protected].

Link outs

Free resources

Other Literature Sources:

Subscription / membership required

Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.