Vessel extraction from non-fluorescein fundus images using orientation-aware detector.

Benjun Yin, Huating Li, Bin Sheng, Xuhong Hou, Yan Chen, Wen Wu, Ping Li, Ruimin Shen, Yuqian Bao, Weiping Jia

Journal: Medical image analysis 2016;26(1):232-42

PMID: 26474120

Abstract

The automatic extraction of blood vessels in non-fluorescein eye fundus images is a tough task in applications such as diabetic retinopathy screening. However, vessel shapes have complex variations, and accurate modeling of retinal vascular structures is challenging. We have therefore developed a new approach to accurately extract blood vessels in non-fluorescein fundus images using an orientation-aware detector (OAD). The detector was designed according to the intrinsic property of vessels being locally oriented and having linearly elongated structures. We employ the OAD to extract vessel shapes with no assumptions on parametric orientations of vessel shapes. The orientations of vessels can be efficiently modeled by the energy distribution of Fourier transformation. Accordingly, both wide and thin vessels can be extracted with two-scale segmentation in which line operators are applied in large scale and the Gabor filter bank is applied in small scale. A post-processing technique, based on the path opening operation, is applied to eliminate false responses to nonvascular areas, such as retinal structures (optic disc and macula) and pathologies (exudates, hemorrhages,and microaneurysms). This makes the detector robust and structure-aware. By achieving a competitive CAL measurement of 80.82% for the DRIVE database and 68.94% for the STARE, the experimental results demonstrated that the OAD approach outperforms existing segmentation methods. Furthermore, the proposed approach effectively works with non-fluorescein fundus images and proves highly accurate and robust in complicated regions such as the central reflex, close vessels, and crossover points, despite a high level of illumination noise in the original data.

Copyright © 2015 Elsevier B.V. All rights reserved.

Address: Department of Computer Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.; Department of Endocrinology and Metabolism, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai Clinical Center for Diabetes, Shanghai Diabetes Institute, Shanghai Key Laboratory of Diabetes Mellitus, Shanghai Key Clinical Center for Metabolic Disease, Shanghai 200240, China.; Department of Computer Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China. Electronic address: [email protected].; Department of Ophthalmology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200240, China.; Department of Computer and Information Science, Faculty of Science and Technology, University of Macau, Macao.; Department of Mathematics and Information Technology, The Hong Kong Institute of Education, Hong Kong.

Link outs

Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.