Z Heetun, R Crowley, F Zeb, D Kearns, M H Brennan, C O'Connor, G Courtney, A R Aftab
Journal: Irish journal of medical science 2017;185(3):629-633
PMID: 26024926
INTRODUCTION
Adequate bowel preparation is necessary for a complete colonoscopy. Polyethylene glycol-electrolyte oral solution (PEG-EOS), sodium picosulphate (SS) and sodium biphosphonate (SP) are the three most commonly used purgative agents. We aimed to determine their efficacy and tolerability compared to each other in a randomised study.
METHODS
313 patients were randomly assigned to receive either PEG-EOS, SS or SP. Patients completed a tolerability score pre-colonoscopy. A cleanliness score was used to document adequacy of bowel preparation. A separate group of patients completed taste scores for the three cathartic agents before and after addition of flavour.
RESULTS
PEG-EOS was the worst-tolerated regimen but achieved the highest rates of right colonic cleansing and the lowest rate of incomplete colonoscopies. There were no statistical differences in the rates of rectosigmoid and mid-gut cleansing among the three agents. SS was by far the preferred purgative in the taste assessment study. Addition of flavour increased significantly taste scores for PEG-EOS.
CONCLUSION
For adequate bowel cleansing PEG-EOS is the most effective but is the least tolerated and least preferred among patients. Addition of flavour increases significantly patients' acceptance of PEG-EOS.