Jacobo Velázquez-Aviña, Ryan Beyer, Claudia P Díaz-Tobar, Shajan Peter, Kondal R Kyanam Kabir Baig, C Mel Wilcox, Klaus Mönkemüller
Journal: Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society 2015;27(3):317-22
PMID: 25211635
BACKGROUND AND AIM
Direct percutaneous endoscopic jejunostomy (DPEJ) is a useful method to provide nutrition to patients with a variety of gastrointestinal (GI) problems. The present study describes a new method of DPEJ using balloon-assisted-enteroscopy.
METHODS
This observational, retrospective, single-arm case study conducted at a tertiary care hospital during a 15-month period included 25 patients (12 females, 13 males, mean age 54 years, age range 31-79 years) with necrotizing pancreatitis, n = 7; complex upper GI surgery, n = 6; complex fistula, n = 6; impossibility to place a gastrostomy tube, n = 5; and bowel obstruction, n = 1. The new DPEJ technique focused on three key components: (i) use of balloon-assisted overtube; (ii) use of fluoroscopy; (iii) leaving the overtube in place during the entire procedure (and also for DPEJ removal).
RESULTS
Technical success was 96%. Mean time of the procedure was 30.5 min (range 24 to 45 min). Clinical success was 100% (24/24); all DPEJ could be used for their intended purpose.
CONCLUSIONS
This new method of inserting a DPEJ using balloon enteroscopy and fluoroscopy was safe and successful. Future comparative studies are now warranted.