Polyetheretherketone (PEEK) cages in cervical applications: a systematic review.

Roel Frederik Mark Raymond Kersten, Steven M van Gaalen, Arthur de Gast, F Cumhur Öner

Journal: The spine journal : official journal of the North American Spine Society 2015;15(6):1446-60

PMID: 24374100

Abstract

BACKGROUND CONTEXT

Polyetheretherketone (PEEK) cages have been widely used during the past decade in patients with degenerative disorders of the cervical spine. Their radiolucency and low elastic modulus make them attractive attributes for spinal fusion compared with titanium and bone graft. Still, limitations are seen such as pseudoarthrosis, subsidence, and migration of the cages. Limited evidence on the clinical outcome of PEEK cages is found in the literature other than noncomparative cohort studies with only a few randomized controlled trials.

PURPOSE

To assess the clinical and radiographic outcome of PEEK cages in the treatment of degenerative disc disorders and/or spondylolisthesis in the cervical spine.

STUDY DESIGN

Systematic review of all randomized controlled trials and prospective and retrospective nonrandomized comparative studies with a minimum follow-up of 6 months and all noncomparative cohort studies with a long-term follow-up of more than 5 years.

OUTCOME MEASURES

The primary outcome variable was clinical performance. Secondary outcome variables consisted of radiographic scores.

METHODS

The MEDLINE, EMBASE, and Cochrane Library databases were searched according to the Preferred Reporting Items of Systematic reviews and Meta-Analyses statement and Meta-analysis Of Observational Studies in Epidemiology guidelines. No conflict of interest reported. No funding received.

RESULTS

A total of 223 studies were identified, of which 10 studies were included. These comprised two randomized controlled trials, five prospective comparative trials, and three retrospective comparative trials.

CONCLUSIONS

Minimal evidence for better clinical and radiographic outcome is found for PEEK cages compared with bone grafts in the cervical spine. No differences were found between PEEK, titanium, and carbon fiber cages. Future studies are needed to improve methodology to minimize bias. Publication of lumbar interbody fusion studies needs to be promoted because differences in clinical and/or radiographic scores are more likely to be demonstrated in this part of the spine.

Copyright © 2015 Elsevier Inc. All rights reserved.

Address: Department of Orthopaedics, Clinical Orthopaedic Research Center midden-Nederland (CORC-mN), Diakonessenhuis Hospital Utrecht/Zeist, PO Box 80250, 3508 TG Utrecht, The Netherlands. Electronic address: [email protected].; Department of Orthopaedics, Clinical Orthopaedic Research Center midden-Nederland (CORC-mN), Diakonessenhuis Hospital Utrecht/Zeist, PO Box 80250, 3508 TG Utrecht, The Netherlands.; Department of Orthopaedics, University Medical Center Utrecht, Utrecht, The Netherlands.