A systematic review of thyroid dysfunction in preterm neonates exposed to topical iodine.

Julie Aitken, Fiona L R Williams

Journal: Archives of disease in childhood. Fetal and neonatal edition 2014;99(1):F21-8

PMID: 24105624

Abstract

OBJECTIVE

To determine whether maternal exposure to iodine or neonatal exposure to topical iodine-containing solutions increases the risk of transient thyroid dysfunction in neonates born <32 weeks' gestation or <1.5 kg.

DESIGN

Systematic review.

SEARCH STRATEGY

Electronic searches were conducted using Medline and the Cochrane Library.

ELIGIBILITY CRITERIA

A study was eligible for review if it reported neonatal exposure to topical iodine or maternal iodine exposure. The key outcome measure was neonatal thyroid function. The search had no restrictions on date of publication, type of study or language.

RESULTS

794 papers were identified during the initial search; 15 studies were fully reviewed. The incidence of (transient) hypothyroidism/hyperthyrotropinaemia following exposure to topical iodine ranged from 12 to 33 per 100 infants; the incidence in non-exposed infants was 0.

CONCLUSIONS

There is evidence that neonatal exposure to iodine-containing disinfectants causes thyroid dysfunction in infants born <32 weeks. None of the studies evaluated neurodevelopment. Larger scale studies are needed to determine definitively the nature of the relationship and the impact of exposure on neurodevelopment. In the meantime, it would seem prudent to restrict exposure of iodine-containing skin disinfectants in preterm infants; chlorhexidine might be a credible alternative.