Evaluation of the suitability of chromatographic systems to predict human skin permeation of neutral compounds.

Marta Hidalgo-Rodríguez, Sara Soriano-Meseguer, Elisabet Fuguet, Clara Ràfols, Martí Rosés

Journal: European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences 2014;50(5):557-68

PMID: 23602997

Abstract

Several chromatographic systems (three systems of high-performance liquid chromatography and two micellar electrokinetic chromatography systems) besides the reference octanol-water partition system are evaluated by a systematic procedure previously proposed in order to know their ability to model human skin permeation. The precision achieved when skin-water permeability coefficients are correlated against chromatographic retention factors is predicted within the framework of the solvation parameter model. It consists in estimating the contribution of error due to the biological and chromatographic data, as well as the error coming from the dissimilarity between the human skin permeation and the chromatographic systems. Both predictions and experimental tests show that all correlations are greatly affected by the considerable uncertainty of the skin permeability data and the error associated to the dissimilarity between the systems. Correlations with much better predictive abilities are achieved when the volume of the solute is used as additional variable, which illustrates the main roles of both lipophilicity and size of the solute to penetrate through the skin. In this way, the considered systems are able to give precise estimations of human skin permeability coefficients. In particular, the HPLC systems with common C18 columns provide the best performances in emulating the permeation of neutral compounds from aqueous solution through the human skin. As a result, a methodology based on easy, fast, and economical HPLC measurements in a common C18 column has been developed. After a validation based on training and test sets, the method has been applied with good results to the estimation of skin permeation of several hormones and pesticides.

Copyright © 2013 Elsevier B.V. All rights reserved.

Address: Departament de Química Analítica and Institut de Biomedicina de la Universitat de Barcelona, Universitat de Barcelona, Martí i Franquès, 1-11, E-08028 Barcelona, Spain.
Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.