A pilot study to assess the hemostatic function of pathogen-reduced platelets in patients with thrombocytopenia.

Pär I Johansson, Anne Catrine Simonsen, Peter N Brown, Sisse R Ostrowski, Liesbeth Deberdt, Pascale Van Hoydonck, Susan S Yonemura, Raymond P Goodrich

Journal: Transfusion 2013;53(9):2043-52

PMID: 23278371

Abstract

BACKGROUND

Platelet (PLT) support is critical to the care of patients with thrombocytopenia, but allogeneic transfusions carry risk. Pathogen reduction mitigates some transfusion risks, but effects on PLT function remain a concern. This clinical pilot study assessed the effect of pathogen reduction technology with riboflavin plus ultraviolet light using thrombelastography (TEG).

STUDY DESIGN AND METHODS

This prospective, randomized, crossover study compared Mirasol-treated (MIR) and standard reference (REF) PLT transfusions. PLT counts and TEG measurements were taken at pretransfusion and 1- and 24-hour-posttransfusion time points. The primary outcome measure was the pretransfusion to 1-hour-posttransfusion change in maximum amplitude (ΔMA(1 hr)). Secondary endpoints included ΔMA among other time points, relative MA, and the PLT count-MA correlation.

RESULTS

Of 16 enrolled patients, one withdrew before study treatment and three did not require two transfusions, leaving 12 patients in the efficacy analyses (seven MIR-REF, five REF-MIR). ΔMA(1 hr) (mean ± SD) was 10.60 ± 6.47 mm for MIR and 14.33 ± 5.38 mm for REF (p = 0.20, n = 10). ΔMA(24hr) was 9.49 ± 7.94 for MIR and 7.13 ± 3.08 for REF (p = 0.38, n = 9); ΔMA(24hr-1 hr) was -1.11 ± 2.95 for MIR and -7.20 ± 4.81 for REF (p = 0.016, n = 8). MA values for MIR and REF correlated with the log of PLT count (rMIR = 0.6901, rREF = 0.7399).

CONCLUSION

TEG is sensitive to changes in hemostatic function resulting from a single PLT transfusion. MIR and REF provided similar increments in hemostatic function in the immediate posttransfusion period and at 24 hours. A significant difference detected for ΔMA(24hr-1 hr) suggests different PLT clearance mechanisms. The relationship of these variables to clinically meaningful outcomes, for example, bleeding events or transfusion requirements, has yet to be determined.

© 2012 American Association of Blood Banks.

Address: Department of Clinical Immunology, Section of Transfusion Medicine, Copenhagen, Denmark; Department of Hematology, University of Copenhagen, Copenhagen, Denmark; Terumo BCT, Lakewood, Colorado.