T Laube, D Flühs, C Kessler, N Bornfeld
Journal: Ophthalmology 2000;107(2):366-8; discussion 368-9
PMID: 10690840
OBJECTIVE
Validation of dosimetry and exposition time to an ophthalmic surgeon during radioactive plaque operations.
DESIGN
Experimental study in which videotaped operations and dosimetric measurements were used to model dosimetry.
METHODS
We used thermoluminescence detectors for high sensitivity readings in radiation fields. Typical intersurgical mobility was videotaped and distances to the plaque was evaluated.
MAIN OUTCOME MEASURE
Estimated radiation received by surgeons.
RESULTS
All simulated plaque operations have a maximum dose rate of 6 mGy per minute (value in the inner eyeball). Mean dose rate is 2 mGy per minute (average of approximately all measurements). The surgeon's fingers receive a dose from 2 to 6 mSv from plaque operation.
CONCLUSIONS
Results suggest that radioactive plaque operations are safe for the surgeon but that the time for plaque handling should be minimized. A surgeon should not exceed 100 to 200 operations per year.
Full Text Sources: