Qutaiba Amir Tawfic, Pradipta Bhakta, Rohit Raman Date, Pradeep Kumar Sharma
Journal: Acta anaesthesiologica Taiwanica : official journal of the Taiwan Society of Anesthesiologists 2013;50(4):188-90
PMID: 23385044
Enteral feeding is now standard and routine practice in intensive care. The use of a nasogastric tube for enteral feeding is generally considered to be safe, but tubes with small bores can sometimes lead to aspiration or passage clogging when malpositioned in sedated patients who are on long-term mechanical ventilation. Thus, accurate confirmation of correct placement is mandatory in such patients. This is not always the case, but this faulty practice can lead to serious complications in the absence of potential bezoar-forming medicines or gastrointestinal pathology. We present here one such interesting case of a patient who developed esophageal bezoar due to a malpositioned nasogastric tube for administering a casein-containing feed. In addition, we present a review of the literature.
Copyright © 2012. Published by Elsevier B.V.