Arun Nair, Lorna McKinlay, Peter Williamson, Philip Short, Patricia Burns, Brian J Lipworth
Journal: European journal of clinical pharmacology 2011;67(4):355-363
PMID: 21240480
PURPOSE
This study compares the in vivo relative lung bioavailability of Hydrofluoroalkane (HFA) Seretide delivered via unprimed and unwashed Aerochamber Plus (AP) or Volumatic (VM) spacers, a integrated breath-actuated vortex Synchro-Breathe (SB) device and an Evohaler pMDI (EH) device using adrenal suppression and early fall in serum potassium (K) as surrogates for respirable dose.
METHODS
Seventeen healthy volunteers completed this randomised double-blind, double-dummy crossover study. Single doses of placebo/Seretide 250 (total dose ex valve fluticasone 2000 mcg/salmeterol 200 mcg) were administered via the devices. Overnight urinary cortisol/creatinine (OUCC) and serum K were measured at baseline and after each dose.
RESULTS
Significant suppression of OUCC and K occurred from baseline with the SB, AP and VM but not with the EH devices. The geometric mean fold suppression (95% confidence interval, p) was: EH, 1.59 (0.80-3.14, p=0.40); AP, 4.26 (3.01-6.02, p<0.001); VM, 3.11 (1.99-4.78, p<0. 001); SB, 3.29 (2.04-5.24, p<0.001). For K, the arithmetic mean fall (mmol/l) (95% confidence interval; p) was: EH, -0.10 (-0.25-0.05, p=0.18); AP, -0.23 (-0.41 to -0.04, p=0.02); VM, -0.22 (-0.44 to -0.01, p=0.04); SB, -0.28 (-0.42 to -0.13, p=0.001).
CONCLUSIONS
The breath-actuated SB device was comparable to 'out of the box' small and large volume spacers and produced similar improvements in relative systemic lung bioavailability for fluticasone and salmeterol.
Full Text Sources:
© Copyright 2026, Nutrition Evidence
We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.